64
7.1.23 TriggerSource
Specifies the internal signal or physical input Line to use as the trigger source. The se
-
lected trigger must have its
TriggerMode
set to On.
Name
TriggerSource
Category
AcqusitionControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
Action1
Specifies which Action command to use as internal
source for the trigger.
All
All trigger sources are active.
Counter1End
(≥ Rel. 2 only)
Specifies which of the Counter signal to use as internal
source for the trigger.
Counter2End
(≥ Rel. 2 only)
Specifies which of the Counter signal to use as internal
source for the trigger.
Line0
Specifies which physical line (or pin) and associated I/O
control block to use as external source for the trigger
signal.
Line1
Specifies which physical line (or pin) and associated I/O
control block to use as external source for the trigger
signal.
Off
No trigger source is active.
Software
Specifies that the trigger source will be generated by
software using the TriggerSoftware command.