204
7.20.4.13
PtpSyncMessageIntervalStatus (≥ Release 3 only)
Returns if the latched sync message interval from the PTP master clock is supported by
the device. An unsupported sync message interval may result in PtpServoStatus instabil-
ity.
Name
PtpSyncMessageIntervalStatus
Category
TansportLayerControl
→
PtpControl
Interface
IEnumeration
Access
Read only
Unit
-
Values
Valid
Sync message interval is valid and supported by the de-
vice.
Invalid
Sync message interval is not valid. This may result in
PtpServoStatus instability.
7.21 Category: UserSetControl
Category that contains the User Set control features. It allows loading or saving factory or
user-defined settings.
Loading the factory default User Set guarantees a state where a continuous acquisition
can be started using only the mandatory features.
These user sets are stored within the camera and can be loaded, saved and transferred
to other cameras.
By using
User Set Default
one of these four user sets can be set as the default, which
means that the camera starts up with these adjusted parameters.
7.21.1 UserSetDefault
Four user sets are available for this camera.
User Set 1
,
User Set 2
,
User Set 3
are user-
specific and can contain user-definable parameters.
Selects the feature
UserSet
to load and make active by default when the device is reset.
The factory settings are stored in the user set
Default
. This is the only user set that cannot
be edited.
Notice
All saved user sets can be set as default.
Name
UserSetDefault
Category
UserSetControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
Default
Select the factory setting user set.
User Set 1
Select the User Set 1 (available when saved).
User Set 2
Select the User Set 2 (available when saved).
User Set 3
Select the User Set 3 (available when saved).