184
7.19 Category: TransferControl
Category for the data Transfer Control features.
7.19.1 TransferStart
Starts the streaming of data blocks out of the device.
If the TransferStart feature is not writable (locked), the application should not start the
transfer and should avoid using the feature until it becomes writable again.
Name
TransferStart
Category
TansferControl
Interface
ICommand
Access
Write only
Unit
-
Values
-
7.19.2 TransferStatus
Reads the status of the Transfer module signal selected by
TransferStatusSelector
.
Name
TransferStatus
Category
TansferControl
Interface
IBoolean
Access
Read only
Unit
-
Values
true = 1 (On)
false = 0 (Off)
7.19.3 TransferStatusSelector
Selects which status of the transfer module to read.
Name
TransferStatusSelector
Category
TansferControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
Stopped
Data block transmission is stopped.
Streaming
Data blocks are transmitted when enough data is avail-
able.