background image

WIRELESS RECEIVER 

ALERT WITH BED  

SHAKER AND  

12V POWER ADAPTER 

Model #: CAS-WCR • Made in PRC

Personal Safety Corporation • Hiawatha, Iowa 52233 • 800.373.2873 • www.SecureSafetySolu

tions.com

POWER

MOUNTING

CODE MATCHING & MELODY SELECTION

Step 1:  Insert batteries into the  

transmitter to be used.  
(CAS-FAM Fall Alarm  
Monitor, CAS-SPT  
Sensor Pad Transmitter 
& Call Button, CAS-PIR 
Motion Detector,  
CAS-DWA Door/ 
Window Alarm,  
CAS-TPC Toilet  
Pull Cord Alert)

Step 2:  Insert 3x C batteries 

into the CAS-WCR  
wireless receiver (Figure 2). 

Step 3:  Enter receiver pairing mode by pressing and holding 

the zone select button for a few seconds until zone 
light “I” begins to flash.

Step 4:  Press the zone select button   again to switch 

to the zone you wish to pair with. Press melody  
selector   to scroll through the melodies.  

Once you hear your preferred melody, do not press 
again as it is now selected.

Step 5:  Once the zone and melody are selected with the 

zone icon flashing, trigger the transmitter once to 
pair. If successful, the receiver will generate a short 
tone. Press the   button to exit pairing mode, the 
system is ready to use.

To stop the melody/alarm while it is alerting press the 
reset button.

Clearing a  

Transmitter  

from the  

Receiver  

Memory

Press and hold the   zone selector button for 3 seconds to 
enter the pairing mode. Press the   zone selector button to 
move to the desired zone you want to delete. Press & hold 
the   zone selector button &   melody selector button 

together for 3 seconds to delete the memory. The receiver 
will generate a tone to indicate the transmitter on the 
specific zone selected has been deleted.

Changing Zone Melody/Alarm Sound

Press and hold the   zone selector button for 3 seconds to 
enter the pairing mode. Press the   zone selector button to 
move to the desired zone then press the   melody selector 

button to select the melody desired. Press the   zone 
selector button until the pairing mode is exited.

Low Battery Indicator

If a zone LED light begins blinking when in standby, it is an 
indication that the batteries in the paired transmitter are 
running low. Replace the transmitter batteries as soon as 
possible.
If the receiver strobe light begins blinking every 5 seconds 
when in standby, the receiver batteries are running low. 
Replace the receiver batteries as soon as possible.

Note

Press the receiver RESET button to cancel an alert. The 
RESET button is located on the back of the receiver behind 
the flasher.

Figure 2

Click here to view detailed product descriptions and prices.

      

Call 800-397-5899 to order today!