58
7.1.9 AcquisitionStop
Stops the Acquisition of the device at the end of the current Frame.
Name
AcquisitionStop
Category
AcqusitionControl
Interface
ICommand
Access
Write only
Unit
-
Values
-
7.1.10
ExposureAuto (≥ Release 2 only)
Sets the automatic exposure mode when ExposureMode is Timed. The exact algorithm
used to implement this control is device-specific.
Name
ExposureAuto
Category
AcqusitionControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
Continuous
Exposure duration is constantly adapted by the device to
maximize the dynamic range.
Off
Exposure duration is user controlled using Exposure-
Time.
Once
Exposure duration is adapted once by the device. Once
it has converged, it returns to the Off state.
7.1.11 ExposureMode
Sets the operation mode of the Exposure (or shutter).
Name
ExposureMode
Category
AcqusitionControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
Timed
Timed exposure. The exposure duration time is set using the
ExposureTime or ExposureAuto features and the exposure
starts with the FrameStart or LineStart.