background image

Solar 

Sikring

CombiProtect

1. FEATURES 

Wireless sensor Ajax CombiProtect is designated for human motion de-

tection and glassbreak detection. It functions as a part of Ajax security 

system. 

2. SPECIFICATIONS  

SPECIFICATION 

MEANING 

Sensor type 

wireless 

Uses

indoors 

Movement detection distance 

up to 12 m (39.4 ft)

Movement and glassbreak sensitivity 3 levels adjustable (low, medium, high) 
Movement detection angle 

88.5° horizontal / 80° vertical

Installation height suggested

2.4 m (7.9 ft)

Pet ignoring option 

Weight up to 20 kg (44 lb), size up to 50 
cm (19.7 in) 

Glassbreak detection distance 

up to 9 m (29.5 ft)

Detecting element 

pyrosensor (movement), electret micro-
phone (glassbreak) 

Tamper protection  

available

Radio signal power

20 mW 

Radio-frequency range 

868 MHz (Europe); 915 MHz (USA)

Maximum distance between sensor 
and central unit

2000 m (6562 ft) (open area) 

Power supply

CR123A battery

Power supply voltage 

3V 

Battery life

Up to 7 years 

Operation temperatures range

from 0°С (+32°F) to +50°С (+122°F)

Operation humidity 

up to 80% 

Dimensions

110х65x50 mm (4.33x2.55x1.96 in)

3. COMPONENTS 

CombiProtect sensor, battery CR123A, installation set, manual

4. GETTING STARTED

4.1  Before  installing  the  sensor,  it  is  required  to  register  it  with  the 

Ajax security system. In order to register the sensor, it is necessary to 

switch the Ajax security system’s receiver to «Add Device» mode (the 

receiver’s manual explains how to accomplish it) and to put the switch 

«2» (PICTURE 4) on the sensor to the «ON» position. The sensor’s light 

must blink at the moment of switching on. The registration request is 

transmitted at the moment the sensor is switched on only! In case the 

registration was not successful, switch off the sensor, wait for 5 sec-

onds and switch it on again. If the sensor’s light blinks constantly (each 

second during one minute), it means that the sensor is not registered. 

The light blinks in the same way if the sensor is deleted from the reg-

istration list. Non-registered sensor blinks also throughout 3 seconds 

during each activation. 

4.2 Having registered the sensor successfully, select an appropriate lo-

cation to install it.

 ATTENTION!

Make sure that in the installation location sensor has a stable radio con-

tact with the receiver! A maximum distance of 2000 m (6562 ft) between 

the sensor and the receiver is mentioned as a comparison with other 

devices. This distance was found as a result of open area tests. Con-

nection quality and distance between the sensor and the receiver can 

vary  depending  on  installation  location,  walls,  compartments,  bridg-

ings, as well as the thickness and constructional material. Signal com-

ing through the obstacles, loses power. For example, distance range 

between the sensor and receiver, divided with two reinforced concrete 

bearing walls, constitutes approximately 30 m (98.4 ft). Please note that 

moving the sensor even 10 cm (4 in), it is possible to improve the signal 

reception considerably. 

 ATTENTION!

Signal level test and detection zone test for sensors take some time to 

start. A certain period of time is necessary for the receiver to send a test 

request to the sensor, and for the sensor to send a test response.

 ATTENTION!

Be careful while SmartBracket installing. Overexertion while installing 

can cause deformation and, as a result, impossibility to install the sen-

sor or to its unreliable fastening. Fix the SmartBracket with the set’s 

assembling units only! Other fixing system use, for example, self-tap-

ping screws of big diameter, can damage fastening clip. Together with 

self-tapping screws, there is a double stick tape in the set. It can be used 

for temporary sensor fixing only. It is recommended not to use the tape 

for the permanent fixing, as the tape dries up over time and the sen-

sor may fall down which can interfere with its functions or even cause 

a breakdown. 

Before installation make sure to check the signal level test in the place 

where you intend to install the sensor! It is possible to launch a signal 

strength test on the receiver’s side. Test launching is described in the 

receiver’s manual.  

RECEIVER

SENSOR'S LIGHT EMITTING DIODE  DESCRIPTION

3 indication bars 

lights almost permanently, with 
short breaks each 1.5 seconds 

excellent signal 

2 indication bars blinks 5 times per second

medium signal 

1 indication bar

blinks twice per second

low signal

0 bars

short flashes each 1.5 seconds 

no signal 

5. INSTALLATION 

5.1 The sensor must be installed in such a way that the intruder’s as-

sumed  entrance  was  perpendicular  to  the  sensor’s  lens  axis.  Glass-

break detection area is also to be considered. The sensor’s microphone 

is not to be turned from the window further that to 90°. Make sure to 

check if the sensor is functioning at the point where it is going to be 

installed!  

5.2 In order to install the sensor, move the plastic fastening clip Smart-

Bracket (PICTURE 1) alongside the frame and remove it. 

5.3 Install the fastening clip SmartBracket on the wall with a help of the 

expansion bolts and self-tapping screws included in the set (PICTURE 

2). The height suggested for the sensor installation is 2.4 m (7.9 ft).     

5.4 Put the sensor on the SmartBracket. Once the sensor is fixed on the 

SmartBracket, its light must blink. It means that the tamper on the sen-

sor is shut. In case the sensor does not blink, the tamper status must be 

checked at the receiver configuration software!

The signal should be not lower that medium so that the sensor works 

in a stable way! 

PICTURE 1. 

CombiProtect sensor and its SmartBracket

SmartBracket is to be moved 

down and removed

  PICTURE 2. 

SmartBracket wall installation scheme

Solar

 Plus

 Ajax

CombiProtect

Reviews: