7.1.19 TriggerMode
Controls if the selected trigger is active.
Name
TriggerMode
Category
AcqusitionControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
Off
Disables the selected trigger.
On
Enable the selected trigger.
7.1.20
TriggerOverlap
Specifies the type trigger overlap permitted with the previous frame.
Name
TriggerOverlap
Category
AcqusitionControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
Read Out
Trigger is accepted immediately after the exposure period..
7.1.21 TriggerSelector
Selects the type of trigger to configure.
Name
TriggerSelector
Category
AcqusitionControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
Frame Start
Selects the type of trigger to configure.
7.1.22 TriggerSoftware
Generates a internal trigger.
TriggerSource
must be set to Software.
Name
TriggerSoftware
Category
AcqusitionControl
Interface
ICommand
Access
Write only
Unit
-
Values
-
Summary of Contents for 11192208