5. Troubleshooting
Code 7631: “Air out temp low” (Warning)
Situation
Solution
The ambient temperature in the
area of the projector is almost below
the minimum required operating
temperature of the projector.
Make sure that the ambient temperature is within specs: higher then 10°C (50°F). Let
the projector acclimate. Do not ignite the lamp, otherwise there is a risk for condensate.
Defect temperature sensor
(reference 11 image 5-27) which
measures the temperature at the air
outlet (projector rear side).
Replace the temperature sensor at the air outlet channel.
11
Image 5-27
Code 7632: “Air out temp high” (Warning)
Situation
Solution
Blocked air inlet channel.
Ensure that the air inlets are not blocked. Provide a suf
fi
cient free area at the front of the
projector so that fresh air can freely enter the air inlet channel.
The wire unit of the temperature
sensor (NTC) of the air outlet
is disconnected from the Power
distribution board.
Check if the wire unit (reference 11 image 5-28) of the temperature sensor is connected
with the power distribution board.
Malfunction Fan Control board.
Replace the Fan Control Board. See "Replacing the Fan control board", page 278.
Defect temperature sensor
(reference 11 image 5-27) which
measures the temperature at the air
outlet (projector rear side).
Replace the temperature sensor at the air outlet channel.
11
Image 5-28
Code 7633: “Air out temp high” (Error)
This error code is probably preceded by the warning code 7632: “Air out temp high”. The same troubleshooting table can be applied
to.
R5905312 HDF W SERIES 24/01/2013
63
Summary of Contents for HDF W series
Page 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Page 4: ......
Page 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Page 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Page 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Page 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Page 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Page 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Page 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Page 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Page 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Page 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Page 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Page 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Page 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Page 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Page 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Page 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Page 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Page 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Page 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Page 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Page 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...