5. Troubleshooting
Code 6080: “Board id: lamp power supply unknown format” (Warning)
Situation
Solution
Old projector software installed.
The ID parameters of one of the
LPS modules are written in a format
which is not known by the projector
software.
Check if the version of the installed projector software is the latest available version. The
latest version can be downloaded from
https://my.barco.com
.
At least one LPS module has invalid
fi
rmware.
Replace the LPS module. See "Lamp Power Supply", page 169.
Corrupt projector software.
Reinstall the latest projector software.
Code 6081: “Board id: lamp power supply not accessable” (Error)
Situation
Solution
Malfunction of a LPS module. The
projector can not read from one of
the installed LPS modules.
Replace the LPS module. See "Lamp Power Supply", page 169.
Code 6082: “Board id: lamp power supply read error” (Error)
Situation
Solution
Malfunction of a LPS module. The
projector can not read from one of
the installed LPS modules.
Replace the LPS module. See "Lamp Power Supply", page 169.
Code 6083: “Board id: lamp power supply write error” (Error)
Situation
Solution
Malfunction of a LPS module. The
projector can not read from one of
the installed LPS modules.
Replace the LPS module. See "Lamp Power Supply", page 169.
Code 7500: “Setting FCB mode” (Error)
Mode adjustment on the Fan Control Board failed. Error occurred after writing and reading the Mode of the Fan Control Board.
Situation
Solution
No communication with Fan Control
Board.
Check if the yellow wire unit (reference 3 image 5-4 & image 5-5) between the Power
Distribution board and the rear side of the Input & Communication unit is properly
connected.
Malfunction Fan Control Board.
1.
Check the diagnostic LEDs of the Fan Control Board. See service manual chapter
XXXXX
2.
Try to reinstall the software/
fi
rmware of the Fan Control Board.
3.
Replace the Fan Control Board. See "Replacing the Fan control board", page 278.
Error occurs only during the ignition
of the lamp.
Fault on digital/analog/speed detection.
Code 7501: “Setting XLR control” (Error)
Situation
Solution
Voltage adjustment on the XLR
connector failed.
1.
Check if the yellow wire unit (reference 3 image 5-4 & image 5-5) between the
Power Distribution board and the rear side of the Input & Communication unit
is properly connected.
2.
Check the diagnostic LEDs of the Fan Control Board. See service manual chapter
XXXXX
3.
Try to reinstall the software/
fi
rmware of the Fan Control Board.
4.
Replace the Fan Control Board. See "Replacing the Fan control board", page 278.
Code 7600: “Red DMD temp low” (Error)
This error code is probably preceded by the warning code 7601: “Red DMD temp low”. The same troubleshooting table can be
applied to.
R5905312 HDF W SERIES 24/01/2013
53
Summary of Contents for HDF W series
Page 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Page 4: ......
Page 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Page 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Page 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Page 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Page 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Page 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Page 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Page 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Page 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Page 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Page 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Page 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Page 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Page 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Page 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Page 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Page 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Page 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Page 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Page 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Page 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...