Troubleshooting checklist
Code 1691: “Form. PWRGood” (Error)
This error code is not documented because it can normally not appear in the
fi
eld. If this code does appear contact Barco for further
instructions.
Code 1692: “Formatter start failed” (Error)
Situation
Solution
The PMP board failed to start.
1.
Reboot the projector.
2.
Ensure the latest
fi
rmware for the Formatter is installed.
3.
Replace the PMP board. See service manual chapter "Replacing the PMP board",
page 156.
Code 1693: “Blue form. start failed” (Error)
This error code is not documented because it can normally not appear in the
fi
eld. If this code does appear contact Barco for further
instructions.
Code 1694: “Green form. start failed” (Error)
This error code is not documented because it can normally not appear in the
fi
eld. If this code does appear contact Barco for further
instructions.
Code 1695: “Red form. start failed” (Error)
This error code is not documented because it can normally not appear in the
fi
eld. If this code does appear contact Barco for further
instructions.
Code 1696: “Formatter ctrl init failed” (Error)
Situation
Solution
The Formatter failed to initialize.
1.
Reboot the projector.
2.
Ensure the latest
fi
rmware is installed on the PMP board.
3.
Replace the PMP board. See "Replacing the PMP board", page 156.
Code 1697: “Formatter init failed” (Error)
Situation
Solution
The Formatter failed to start.
1.
Reboot the projector.
2.
Ensure the latest projector software is installed.
3.
Replace the PMP board. See "Replacing the PMP board", page 156.
Input & Communication unit is
replaced by a unit used in a Barco
HDQ projector.
Restart the projector and wait for at least 15 to 20 minutes until the formaters are
automatically reprogrammed with the correct software to support the current light
processor resolution. DO NOT SWITCH OFF THE PROJECTOR during this process.
When the projector was switched off before the reprogramming procedure was
fi
nished,
during the next startup the “Formatter init failed” will be displayed. A reprogramming of
the PMP board will be necessary and should be done by Barco. Contact Barco for
further instructions.
Code 1698: “Formatter init failed” (Warning)
This error code can appear sometimes and disappear again. If it appears several times, see code 1697 for more documentation.
Code 2002: “Lamp start failed” (Error)
Situation
Solution
Mains input disconnected from the
LPS power input pins.
Check if the wire units (reference 1, 2 & 3 image 5-1) of the mains voltage are connected
with the power input pins of the LPS modules.
Malfunction lamp in Lamp House.
Install a new xenon lamp in the Lamp House. See "Lamp and lamp house", page 117.
Malfunction of one of the LPS
modules
1.
Check the diagnostic LEDs of the LPS module. See service manual chapter "LPS
module diagnostic LED’s", page 170.
2.
Replace the LPS module. See "Lamp Power Supply", page 169
Malfunction LPS relay (reference 4
image 5-2).
Check the functionality of the LPS relay. Replace if needed.
R5905312 HDF W SERIES 24/01/2013
33
Summary of Contents for HDF W series
Page 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Page 4: ......
Page 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Page 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Page 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Page 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Page 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Page 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Page 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Page 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Page 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Page 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Page 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Page 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Page 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Page 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Page 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Page 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Page 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Page 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Page 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Page 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Page 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...