6. Physical installation stand alone cooler
•
Wall mounting
: When this option is chosen, the cooler must be
fi
xed on the wall in portrait mode or in landscape mode.
In portrait mode, the cooler must be mounted with the cooling tubes up. The other position (cooling tubes down) is not authorized
because coolers are heavy (more or less 15kg) and if the safety clic fails and the cooler screw is not
fi
xed, the cooler will simply
fall to the ground! In this orientation it is also less practical to remove a cooler for service.
A
B
Image 6-5
A
Portrait Mode with cooling tubes to the top.
B
Portrait Mode with cooling tubes down (not authorized)
In landscape mode the cooler must be mounted with the cooling tubes to the left. The other position (cooling tubes to the right)
is not authorized due to technical constraints. Functioning and lifetime of internal pump could be impacted if the unit is installed
in this position.
A
B
Image 6-6
A
Landscape Mode with cooling tubes to the left (only one authorized position).
B
Landscape Mode with cooling tubes to the right (not authorized).
6.2
Assembling the cooler housing
What has to be done?
The cooler housing is delivered as a kit and must be assembled during installation.
R5906753 DPXK BLP SERIES 20/11/2017
53
Summary of Contents for DP2K-17BLP
Page 4: ......
Page 8: ...Table of contents 4 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 30: ...3 Installation process 26 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 40: ...4 Physical installation projector 36 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 120: ...10 Communicator Touch Panel Image 10 7 Connections 116 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 152: ...14 Maintenance 148 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 162: ...16 Color calibration 158 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 176: ...18 Specifications 172 R5906753 DPXK BLP SERIES 20 11 2017 ...