2. General
2. GENERAL
About this chapter
Read this chapter before installing your DPxK BLP-series projector. It contains important information concerning installation re-
quirements for the DPxK BLP-series projector, such as minimum and maximum allowed ambient temperature, humidity conditions,
required safety area around the installed projector, required power net, etc.
Furthermore, careful consideration of things such as image size, ambient light level, projector placement and type of screen to use
are critical to the optimum use of the projection system.
About DPxK BLP-series projectors
•
DP2K-36BLP
•
DP4K-36BLP
•
DP2K-23BLP
•
DP4K-23BLP
•
DP2K-17BLP
•
DP4K-17BLP
Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guar-
antee. Observing the speci
fi
cation mentioned in this chapter is critical for projector performance. Neglecting
this can result in loss of warranty.
After unpacking let the projector acclimatizes to a room temperature higher then 10°C (50°F) and lower then
35°C (95°F). It is suggests only using it after having stored it for 16 hours in
fi
nal location. Neglecting this may
result in a start up failure of the Light Processor Unit.
Overview
•
•
•
•
2.1
Installation requirements
Environmental conditions
The table below summarizes the physical environment in which the DPxK BLP series projector may be safely operated or stored.
Environment
Operating
Non-Operating
Ambient Temperature
10°C (50°F) to 35°C (95°F)
-15°C (5°F) to 60°C (140°F)
Air cleanliness
Clean of
fi
ce environment (equivalent with cleanroom
standard ISO 14644-1 ISO Class 9)
n.a.
Humidity
5% to 85% RH Non-condensed
5% to 95% RH Non-Condensed
Altitude
-60 (-197Ft) to 3000m (9843Ft)
-60 (-197Ft) to 10000m (32810Ft)
Let the projector acclimatize after unpacking. Neglecting this may result in a startup failure of the Light Pro-
cessor Unit.
Use in high altitude conditions
When 3000 m environmental condition is combined with the highest permissible temperature (35°C ambient), the projector may be
expected to go into warning status. Hence, for high altitude conditions, we advise max 30°C ambient condition (25°C is preferred).
Furthermore, to avoid temperature warnings on laser banks, we advise in high altitude to set cooler fans to 100%.
R5906753 DPXK BLP SERIES 20/11/2017
15
Summary of Contents for DP2K-17BLP
Page 4: ......
Page 8: ...Table of contents 4 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 30: ...3 Installation process 26 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 40: ...4 Physical installation projector 36 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 120: ...10 Communicator Touch Panel Image 10 7 Connections 116 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 152: ...14 Maintenance 148 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 162: ...16 Color calibration 158 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 176: ...18 Specifications 172 R5906753 DPXK BLP SERIES 20 11 2017 ...