4. Physical installation projector
Connect directly (A) or drag the cable behind the front cover so that the front cover can be removed without removing the UPS
INLET cable (B).
1
2
A
B
Image 4-15
UPS connection
3. Secure the UPS inlet socket with a
fi
xation spring. Handle as follow:
-
Squeeze the
fi
xation spring together.
-
Slide the
fi
xation spring on the
fi
xation pins while squeezing together and push it against the power plug.
-
Release the
fi
xation spring.
4. Install on the power outlet the second
fi
xation spring to prevent losing it (2).
C
AUTION
:
The electrical connection with the UPS INLET socket of the projector must be done with a certi
fi
ed
AC power supply cord (minimum 0,75 mm² or 18 AWG and minimum 300V)
C
AUTION
:
Do not use the power OUTLET socket of the projector to provide power to other equipment!
R5906753 DPXK BLP SERIES 20/11/2017