background image

 

EN

 

18 

OPERATING INSTRUCTIONS 

Warning 

Before  switching  on  the  heater,  check  that  the  power 
supply specifications are the same as those stated on 
the identification plate. 

 

Warning 

For M DV models, check that the arrows on the voltage 
supply  selector  key  cover  (11)  are  pointing  to  the 
voltage value required, 110V or  230 V. 
If necessary: 
• remove the cover; 
• press switch (11) to the position required; 
• replace the protective cover. 
 

START 

To start the space heater: 
ALL MODELS 
•   Set the pressure regulator to maximum pressure  
•  Slowly open the gas stopcockon the gas cylinder. 
 

Warning 

In  case  of  a  gas  leak,  close  the  gas  stopcock 
immediately,  close  the  gas  cylinder  valve,  switch  off 
the  heater,  remove  the  plug  from  the  electrical  panel, 
and call customer service to find the origin of the leak. 

 
•   Make sure the switch (9) is set to “0”; 
•   Turn on the disconnecting switch on the main electrical panel; 
M AND M DV ALL MODELS 
•   Move the switch (9) to position (I): fan starts; 
•   Press  the  gas  valve  button  (13)  and  simultaneously  press  the 

piezoigniter (12) once or twice until the flame light up. 

•   Keep pressed the gas valve button (13) for 15 / 20 seconds until 

the  thermocouple  is  sufficiently  heated:  when  button  13  is 
released, the flame stays on. 

A MODELS (with or without room thermostat connected) 
•   Move the switch (9): 

 

•   to position        if room thermostat is not connected 
•   to position         if room thermostat is connected and set it to a 

temperature higher than room temperature 

•   Automatic starting cycle starts until the flame lights up. 
If the heater still does not function, see 

“TROUBLESHOOTING” to 

identify the cause of the malfunction. 

 
STOP 

To stop o

peration turn the switch (9) to position “0” if operation is 

manual, or, for A model, turn thermostat adjustment down: the flame 
goes  out  and  the  fan  continues  to  work  for  approximately  90  sec. 
cooling the combustion chamber.

 

Lastly,  close  the  gas  supply  stopcock  and  turn  off  the  isolation 

switch. 

 
 
 
 
 

Warning 

For M model: wait  at  least  2 minutes  before  restarting 
the  heater,  to  allow  the  thermocouple  to  cool 
completely. 

 

Warning 

If  the  heater  is  not  used  continuously,  stop  it  by  first 
closing the gas supply stopcock and then switch it off 
by  pressing  button  (9)  or  by  turning  down  the 
thermostat: 

 

this allows the gas in the gas tube to be fully used and 
avoids any future leak when removing the gas tube. 

 
VENTILATION 

Type M models can be used as fans: simply disconnect gas tube 

from gas bottle and turn the switch (9) to position (I).

 

 

TRANSPORTING AND HANDLING 

The space heater can be lifted and moved by means of its handle. 

 
Warning 

Before moving the unit: 
•   Stop  the  heater  as  indicated  in  the  “STOP” 

paragraph; 

•   Disconnect the power supply by  removing the plug 

from the power socket; 

•   Close  the  gas  stopcock  and  disconnect  the  gas 

hose; 

•   Wait until the heater cools. 

 

Warning 

During  transportation  and/or  storage,  make  sure  the 
gas  valve  group  and  gas  connection  pipes  are  not 
knocked or damaged in any way. 

 

MAINTENANCE 

For  efficient  operation  of  the  heater,  clean  the  fan  motor,  suction 

grill,  combustion  chamber,  and  burner  at  regular  intervals.  Remove 
all debris. 

 
Warning

 

Before doing any maintenance: 
•   Stop  the  heater  as  indicated  in  the  “STOP” 

paragraph; 

•   Disconnect the power supply by  removing the plug 

from the power socket; 

•   Close the gas supply stopcock; 
•   Wait until the heater cools. 

 

Warning 

Incorrect  cleaning  of  the  heater  can  cause  damage  to 
property and/or people. 

 
 
 

 

Summary of Contents for GP 105A

Page 1: ...2 51 GP 105A Code 128...

Page 2: ...OPAR Modelo M M THERMOKOPPEL Modellen M TERMOPARA Model M 7 ELETTRODO DI IONIZZAZIONE Modello A ELECTRODE D IONISATION Mod le A IONISATIONSELEKTRODE Modell A IONISATION ELECTRODE A model ELECTRODO DE...

Page 3: ...nde automaticamente il funzionamento al ripristinarsi del valore di tensione T 195 V per pi di 20 secondi luce verde fissa la macchina in regolare funzionamento ciclo di avviamento o ciclo di lavoro l...

Page 4: ...azione dell aria ne pu derivare un grave pericolo di incendio COLLEGAMENTO ALLA BOMBOLA O BIDONE DI GAS Il generatore d ara calda deve essere collegato ad una bombola o serbatoio di gas di dimensioni...

Page 5: ...ermostato stesso ad una temperatura superiore a quella ambiente Il ciclo di avviamento automatico della macchina inizia automaticamente e termina con l accensione della fiamma Se dopo tali operazioni...

Page 6: ...pulsante della valvola gas termica per almeno 30 secondi Controllare la posizione della termocoppia Estrarre la termocoppia e pulirla Termocoppia difettosa modello M M DV Controllare la termocoppia ed...

Page 7: ...leur de tension T 195 V pendant plus de 20 secondes lumi re verte fixe l appareil fonctionne correctement cycle de d marrage ou de travail lumi re rouge fixe l appareil s arr te de mani re permanente...

Page 8: ...des fort risque d incendie RACCORDEMENT LA BOUTEILLE DE GAZ Le g n rateur d air chaud doit tre raccord une bouteille de gaz de dimensions appropri es apr s interposition d une vanne d arr t de gaz Att...

Page 9: ...iquement lanc et se termine par l allumage de la flamme Si apr s ces op rations le g n rateur ne fonctionne pas il faut consulter le paragraphe ANOMALIES DE FONCTIONNEMENT CAUSES ET SOLUTIONS et d cou...

Page 10: ...e gaz thermique enfonc pendant au moins 30 secondes Contr ler la position du thermocouple D poser le thermocouple et le nettoyer Thermocouple d fectueux mod les M M DV Contr ler le thermocouple et le...

Page 11: ...T 195 V ber einen Zeitraum von mehr als 20 s Dauerlicht Gr n Das Ger t arbeitet ordnungsgem Anlaufbetrieb oder Arbeitsbetrieb Dauerlicht Rot Sicherheitsabschaltung des Ger tes Der Wiederanlauf ist ers...

Page 12: ...sse haben ein linksg ngiges Gewinde und m ssen daher entgegen dem Uhrzeigersinn angezogen werden Achtung Die Abmessungen der Gasflasche oder m ssen in Abh ngigkeit vom verlangten Gasvolumenstrom und d...

Page 13: ...erz glich gestoppt Falls das Ger t nach Ausf hrung der genannten Schritte nicht funktioniert den Abschnitt ST RUNGEN URSACHEN UND ABHILFEN durchlesen und den Grund f r den Funktionsausfall ermitteln S...

Page 14: ...ermoelements kontrollieren Das Thermoelement herausnehmen und reinigen Thermoelement defekt Modell M M DV Das Thermoelement kontrollieren und ggf auswechseln Das Netzkabel ist falsch gepolt Pole L und...

Page 15: ...and can restart only if reset button 8 is pressed GENERAL ADVICE The heater must be installed set up and used in accordance with the applicable regulations and laws relating to the use of such equipme...

Page 16: ...bar The heater is supplied complete with gas hose a and pressure reducer c with fittings d for connection to different types of cylinders Depending on the country of destination the heater may be sup...

Page 17: ...e malfunction STOP To stop operation turn the switch 9 to position 0 if operation is manual or for A model turn thermostat adjustment down the flame goes out and the fan continues to work for approxim...

Page 18: ...positioning Remove thermocouple and clean it Faulty thermocouple M M DV models Check thermocouple and replace it if necessary Electrical power cable is connected with polarities L and N reversed A mod...

Page 19: ...pausa o stand by en espera de la petici n de calefacci n luz naranja parpadeante la m quina se detiene moment neamente T 190 V por m s de 20 segundos y reanuda autom ticamente el funcionamiento al re...

Page 20: ...l termostato ambiente est n indicadas en las instrucciones espec ficas anexas El esquema el ctrico incluido en el presente manual indica exclusivamente la conexi n el ctrica del accesorio al sistema e...

Page 21: ...Presionar el bot n 13 de la v lvula de gas t rmica y al mismo tiempo presionar una o m s veces el encendedor piezoel ctrico 12 hasta obtener que se encienda la llama Mantener presionado el bot n 13 p...

Page 22: ...ra o presente Atenci n Antes de iniciar cualquier operaci n de mantenimiento se debe Detener el aparato seg n las indicaciones del apartado PARADA Desconectar la alimentaci n el ctrica extrayendo el e...

Page 23: ...o el bot n de la v lvula de gas t rmica por al menos 30 segundos Controlar la posici n del termopar Extraer el termopar y limpiarlo Termopar defectuoso modelos M M DV Controlar el termopar y de ser ne...

Page 24: ...RU 25 EN 1596 2008 G31 G30 G31 I U 190 V 20 8 8 U 190 V 20 U 195 V 20 8 2 3 EN 1596 2008 100 3 100 3 25 2 250 2...

Page 25: ...RU 26 L N L N 10 2 a c d I G5 AT BG CY DK DE EE LT LV MK MT RO TR NL G5 G2 G2 BE CZ ES FR HR HU LU PL PT SI SK G5 G1 G1 IT GR G5 G7 G7 FI IE GB G5 G9 G9 SE NO G5 G5R G5R CH NL NL G5 NL...

Page 26: ...RU 27 II G7 FI IE GB III G9 SE NO b 9 0 9 9 0 90 9...

Page 27: ...RU 28 M M DV A 8 M A L N L N 8 V 195 V 195...

Page 28: ...RU 29 RU 0001 11 B51 109599 74 2 XII 109599 74 2 XII 8 495 991 45 42 8 499 372 01 67 C IT AB51 B 02155 12 02 2013 12 02 2015 BIEMMEDUE S p A Via Industria 12 12062 Cherasco CN Italy...

Page 29: ...RU 30 Ballu Biemmedue Ballu Biemmedue 1 2 1 2 3 4 5 6 7 8 9 12 _________________ _________________________________ ____ _______________201__...

Page 30: ..._______________________________________________ ___________________________________________ ______________________________________________________________________________ _____________________________...

Page 31: ...je licht het apparaat stopt tijdelijk T 190 V langer dan 20 seconden en hervat automatisch zijn werking bij het herstellen van de spanningswaarde T 195 V langer dan 20 seconden vast groen licht het ap...

Page 32: ...hitter mag op geen enkel luchtkanalisatiesysteem worden aangesloten hieruit kan ernstig brandgevaar voortvloeien AANSLUITING OP DE GASFLES OF GASTANK De luchtverhitter moet aangesloten worden op een g...

Page 33: ...atuur De automatische startcyclus van het apparaat begint automatisch en eindigt met het branden van de vlam Als na deze handelingen de luchtverhitter niet werkt de paragraaf STORINGEN OORZAKEN EN REM...

Page 34: ...hem eventueel Het thermokoppel wordt niet warm en de thermische gasklep sluit model M M DV Herhaal het starten en houd de knop van de thermische gasklep minstens 30 seconden ingedrukt Controleer de p...

Page 35: ...a dzia anie po przywr ceniu odpowiedniej warto ci napi cia T 195 V przez wi cej ni 20 sekund wiat o zielone sta e urz dzenie dzia a normalnie cykl uruchomienia lub cykl roboczy wiat o czerwone sta e u...

Page 36: ...agrzewnicy powietrza nie wolno pod cza adnych przewod w rozprowadzania powietrza mo e to spowodowa bardzo powa ne zagro enie po arem POD CZENIE DO BUTLI Z GAZEM Nagrzewnica powietrza musi by pod czona...

Page 37: ...znik 9 w pozycji je eli termostat nie jest pod czony w pozycji je eli termostat jest pod czony i nastawi termostat na temperatur wy sz ni temperatura otoczenia Cykl automatycznego uruchomienia urz dze...

Page 38: ...aci ni ty przycisk zaworu termicznego gazu przez co najmniej 30 sekund Sprawdzi ustawienie termopary Wyj termopar i oczy ci j Termopara jest uszkodzona model M M DV Sprawdzi termopar i ewentualnie wym...

Page 39: ...T TERMOSTATO DE SEGURIDAD VEILIGHEIDSTHERMOSTAAT TERMOSTAT ZABEZPIECZAJ CY TA PRESA TERMOSTATO AMBIENTE PRISE THERMOSTAT D AMBIANCE RAUMTHERMOSTAT STECKDOSE ROOM THERMOSTAT PLUG ENCHUFE TERMOSTATO AMB...

Page 40: ...DE REGULACI N DEL TERMOPAR AFSTELSCHEMA THERMOKOPPEL SCHEMAT REGULACJI TERMOPARY A mm GP 105 33 DESTINAZIONE EUROPEA DESTINATION EUROP ENNE BESTIMMUNGSGEBIET EUROPA EUROPE DESTINO EUROPEO EUROPESE BES...

Page 41: ...output Capacidad aire Luchtdebiet Nat enie przep ywu powietrza m3 h 3700 Temperatura min di servizio Temp rature min de service Min Service Temperatur Min service temperature Temperatura m n de servi...

Page 42: ...GLIA ANLEITUNG F R DIE MONTAGE DER R DER DES GRIFFES NOTICE DE MONTAGE DES ROUES DE LA POIGNEE WHEELS HANDLE ASSEMBLING INSTRUCTION INSTRUCCIONES DE MONTAJE RUEDAS MANILLA MONTAGE INSTRUCTIE WIELEN HA...