4-8 Programming & Operation
MN1230
Program Mode Continued
Initialize New Software EEPROMs
After new EEPROMs are installed, the control must be initialized to the new software
version and memory locations. Use the following procedure to Initialize the EEPROMs.
Action
Description
Display
Comments
Apply Power
Keypad Display shows this
opening message.
Logo display for 5 seconds.
If no faults and programmed for
LOCAL operation.
Display mode. Stop LED on.
Press PROG key
Enter program mode.
Press
Y
or
B
key
Scroll to Level 2 Blocks.
Press ENTER key
Select Level 2 Blocks.
Press
Y
or
B
key
Scroll to the Miscellaneous block.
Press ENTER key
Select Miscellaneous block.
Press
Y
key
Scroll to Factory Settings
parameter.
Press ENTER key
Access Factory Settings
parameter.
V
represents blinking cursor.
Press
Y
key
Scroll to YES, to choose original
factory settings.
Press ENTER key
Restores factory settings.
“Loading Presets” is first message
“Operation Done” is next
“No” is displayed last.
Press
Y
key
Scroll to menu exit.
Press ENTER key
Return to display mode.
Display mode. Stop LED on.
Press
Y
key
Scroll to diagnostic info block.
Press ENTER key
Access diagnostic information.
Displays commanded speed,
direction of rotation, Local/
Remote and motor speed.
Press DISP key
Display mode showing software
version and revision installed in
the control.
XXX-X.XX
Verify new software version.
Press DISP key
Displays exit choice.
Press ENTER to exit diagnostic
information.
Summary of Contents for 29M
Page 1: ...Series 29M Servo Control Installation Operating Manual 1 98 MN1230 AC SERVO DRIVE...
Page 5: ...Section 1 General Information iv Table of Contents MN1230...
Page 7: ...Section 1 General Information 1 2 Receiving Inspection MN1230...
Page 45: ...Section 1 General Information 3 34 Installation MN1230...
Page 94: ...Section 1 General Information Specifications and Product Data 7 7 MN1230 Dimensions...
Page 102: ...Appendix B Appendix B 1 MN1230...