Section 1
General Information
Appendix A
Appendix A-5
MN1230
Parameter Block Values Level 2
Continued
Level 2 Blocks - Continued
Block Title
Parameter
P#
Adjustable Range
Factory
Setting
User
Setting
PROCESS
CONTROL
PROCESS FEEDBACK
2601
POTENTIOMETER
+/-10VOLTS
+/-5 VOLTS
4 TO 20 mA
5V EXB
10V EXB
4-20mA EXB
3-15 PSI EXB
TACHOMETER EXB
NONE
NONE
PROCESS INVERSE
2602
ON, OFF
OFF
SETPOINT SOURCE
2603
SETPOINT CMD
POTENTIOMETER
+/-10VOLTS
+/-5 VOLTS
4 TO 20 mA
5V EXB
10V EXB
4-20mA EXB
3-15 PSI EXB
TACHOMETER EXB
NONE
SETPOINT
CMD
SETPOINT COMMAND
2604
–100% to +100%
0.0 %
SET PT ADJ LIMIT
2605
0-100%
10.0 %
PROCESS ERR TOL
2606
0-100%
10 %
PROCESS PROP GAIN
2607
0-2000
0
PROCESS INT GAIN
2608
0-9.99 HZ
0.00 HZ
PROCESS DIFF GAIN
2609
0-1000
0
FOLLOW I:O RATIO
2610
(1-65535) : (1-65535)
1:1
FOLLOW I:O OUT
2611
(1-65535) : (1-65535)
1:1
MASTER ENCODER
2612
50 - 65535
1024PPR
COMMUNICATIONS
PROTOCOL
2701
RS232 ASCII, RS 485 ASCII
RS232
ASCII
BAUD RATE
2702
9600, 19.2KB, 38.4KB, 57.6KB,
115.2KB, 230.4KB
9600
DRIVE ADDRESS
2703
0 - 31
0
Summary of Contents for 29M
Page 1: ...Series 29M Servo Control Installation Operating Manual 1 98 MN1230 AC SERVO DRIVE...
Page 5: ...Section 1 General Information iv Table of Contents MN1230...
Page 7: ...Section 1 General Information 1 2 Receiving Inspection MN1230...
Page 45: ...Section 1 General Information 3 34 Installation MN1230...
Page 94: ...Section 1 General Information Specifications and Product Data 7 7 MN1230 Dimensions...
Page 102: ...Appendix B Appendix B 1 MN1230...