Section 1
General Information
Installation 3-17
MN1230
Figure 3-9 15 Speed 2-Wire Mode Connection Diagram
ACC/DEC/“S” SELECT
ENABLE
FORWARD ENABLE
REVERSE ENABLE
SWITCH 1
SWITCH 2
SWITCH 3
EXTERNAL TRIP
J1A
ANALOG OUT 1
ANALOG OUT 2
CREF
OUT 1–
OUT 1+
OUT 2–
1
2
3
4
5
6
7
SWITCH 4
ANALOG GND
Both CLOSED= Forward
Both OPEN = Stop
All CLOSED= Fault
Reset
J1B
OUT 2+
OUT 3–
OUT 3+
OUT 4–
OUT 4+
OUT 1
OUT 2
OUT 3
OUT 4
Note 1
Note 2
No
Connection
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Notes:
1.
Refer to Analog Outputs description in this section.
2.
Refer to Opto Isolated Outputs description in this
section.
Refer to Figure 3-17
N.C.
V
ext
N.C.
GND
ext
Customer
Supplied
+24VDC Source
J1B-8
CLOSED allows current to flow in the motor and produce torque.
OPEN disables the control & motor coasts to a stop.
J1B-9
CLOSED operates the motor in the Forward direction.
OPEN coasts brakes to stop depending on Keypad Stop mode parameter setting.
J1B-10
CLOSED operates motor in the Reverse direction.
OPEN coasts or brakes to stop depending on Keypad Stop mode parameter setting.
J1B-11 to 14
Selects programmed preset speeds as defined in Table 3-5.
J1B-15
Selects ACC/DEC group. CLOSED selects group 2. OPEN selects group 1.
J1B-16
OPEN causes an external trip to be received by control. The control will disable and
display External Trip when programmed “ON”. If J1B-16 is connected, you must set
Level 2 Protection block, External Trip to “ON” to recognize the J1B-16 input.
Summary of Contents for 29M
Page 1: ...Series 29M Servo Control Installation Operating Manual 1 98 MN1230 AC SERVO DRIVE...
Page 5: ...Section 1 General Information iv Table of Contents MN1230...
Page 7: ...Section 1 General Information 1 2 Receiving Inspection MN1230...
Page 45: ...Section 1 General Information 3 34 Installation MN1230...
Page 94: ...Section 1 General Information Specifications and Product Data 7 7 MN1230 Dimensions...
Page 102: ...Appendix B Appendix B 1 MN1230...