Section 1
General Information
Installation 3-15
MN1230
Figure 3-8 Standard Run 3-Wire Mode Connection Diagram
FAULT RESET
ENABLE
FORWARD ENABLE
REVERSE ENABLE
STOP
Closed=JOG SPEED
ACC/DEC/“S” SELECT
EXTERNAL TRIP
J1A
ANALOG OUT 1
ANALOG OUT 2
OUT 1–
OUT 1+
OUT 2–
1
2
3
4
5
6
7
PRESET SPEED #1
ANALOG GND
ANALOG INPUT 1
POT REFERENCE
ANALOG INPUT 2+
ANALOG INPUT 2–
Both CLOSED= Forward
J1B
OUT 2+
OUT 3–
OUT 3+
OUT 4–
OUT 4+
5k
W
Command Pot
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
OUT 1
OUT 2
OUT 3
OUT 4
Note 2
Note 1
Note 3
Notes:
1.
Refer to Analog Inputs description in this section.
Note: JP1 must be properly set for either voltage or current
operation. Refer to Figure 3-16 for jumper information.
2.
Refer to Analog Outputs description in this section.
3.
Refer to Opto Isolated Outputs description in this section.
Refer to Figure 3-17
N.C.
V
ext
N.C.
GND
ext
CREF
Customer
Supplied
+24VDC Source
J1B-8
CLOSED allows current to flow in the motor and produce torque.
OPEN disables the control and motor coasts to a stop.
J1B-9
Momentary CLOSED starts motor operation in the Forward direction. In JOG mode
(J1-12 CLOSED), continuous CLOSED jogs motor in the Forward direction.
J1B-10
Momentary CLOSED starts motor operation in the Reverse direction. In JOG mode
(J1-12 CLOSED), CONTINUOUS closed JOGS motor in the Reverse direction.
J1B-11
When OPEN control removes power from motor and disables. Coasts or brakes to stop
depending on Keypad Stop Mode parameter setting.
J1B-12
CLOSED places control in JOG mode, Forward and Reverse run are used to jog the
motor.
J1B-13
CLOSED selects group 2.
OPEN selects ACC / DEC / S-CURVE group 1.
J1B-14
CLOSED selects preset speed #1.
OPEN allows speed command from Analog input #1 or #2.
J1B-15
CLOSED to reset fault condition.
OPEN to run,
J1B-16
OPEN causes an external trip to be received by control. The control will disable and
display External Trip when programmed “ON”. If J1B-16 is connected, you must set
Level 2 Protection block, External Trip to “ON” to recognize the J1B-16 input.
Summary of Contents for 29M
Page 1: ...Series 29M Servo Control Installation Operating Manual 1 98 MN1230 AC SERVO DRIVE...
Page 5: ...Section 1 General Information iv Table of Contents MN1230...
Page 7: ...Section 1 General Information 1 2 Receiving Inspection MN1230...
Page 45: ...Section 1 General Information 3 34 Installation MN1230...
Page 94: ...Section 1 General Information Specifications and Product Data 7 7 MN1230 Dimensions...
Page 102: ...Appendix B Appendix B 1 MN1230...