Section 1
General Information
Installation 3-19
MN1230
Figure 3-10 2 Wire Multi INP Mode Connection Diagram
PRESET SPEED #2
ENABLE
FORWARD RUN
REVERSE RUN
ANALOG INPUT SELECT
RUN COMMAND
SPEED COMMAND
EXTERNAL TRIP
J1A
ANALOG OUT 1
ANALOG OUT 2
OUT 1–
OUT 1+
OUT 2–
1
2
3
4
5
6
7
PRESET SPEED #1
ANALOG GND
ANALOG INPUT 1
POT REFERENCE
ANALOG INPUT +2
ANALOG INPUT –2
Both Closed=
Fault Reset
J1B
OUT 2+
OUT 3–
OUT 3+
OUT 4–
OUT 4+
OUT 1
OUT 2
OUT 3
OUT 4
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Note 3
Refer to Figure 3-17.
5k
W
Command Pot
or 0-10VDC
Note 2
Note 1
±
5VDC,
±
10VDC
or 4-20mA
Programmable
Analog Outputs.
Note 1
Notes:
1.
Refer to Analog Inputs description in this section.
Note: JP1 must be properly set for either voltage or current
operation. Refer to Figure 3-16 for jumper information.
2.
Refer to Analog Outputs description in this section.
3.
Refer to Opto Isolated Outputs description in this section.
CREF
N.C.
V
ext
N.C.
GND
ext
Customer
Supplied
+24VDC Source
Summary of Contents for 29M
Page 1: ...Series 29M Servo Control Installation Operating Manual 1 98 MN1230 AC SERVO DRIVE...
Page 5: ...Section 1 General Information iv Table of Contents MN1230...
Page 7: ...Section 1 General Information 1 2 Receiving Inspection MN1230...
Page 45: ...Section 1 General Information 3 34 Installation MN1230...
Page 94: ...Section 1 General Information Specifications and Product Data 7 7 MN1230 Dimensions...