Programming & Operation 4-7
MN1230
Program Mode Continued
Reset Parameters to Factory Settings
Sometimes it is necessary to restore the parameter values to the factory settings. Follow
this procedure to do so.
Note: All specific application parameters already programmed will be lost when
resetting the control to factory settings.
Action
Description
Display
Comments
Apply Power
Keypad Display shows this
opening message.
Logo display for 5 seconds.
If no faults and programmed for
LOCAL operation.
Display mode. Stop LED on.
Press PROG key
Enter program mode.
Press
Y
or
B
key
Scroll to Level 2 Blocks.
Press ENTER key
Select Level 2 Blocks.
Press
Y
or
B
key
Scroll to the Miscellaneous block.
Press ENTER key
Select Miscellaneous block.
Press
Y
key
Scroll to Factory Settings
parameter.
Press ENTER key
Access Factory Settings
parameter.
V
represents blinking cursor.
Press
Y
key
Scroll to YES, to choose original
factory settings.
Press ENTER key
Restores factory settings.
“Loading Presets” is first message
“Operation Done” is next
“No” is displayed last.
Press
Y
key
Scroll to menu exit.
Press ENTER key
Return to display mode.
Display mode. Stop LED on.
Summary of Contents for 29M
Page 1: ...Series 29M Servo Control Installation Operating Manual 1 98 MN1230 AC SERVO DRIVE...
Page 5: ...Section 1 General Information iv Table of Contents MN1230...
Page 7: ...Section 1 General Information 1 2 Receiving Inspection MN1230...
Page 45: ...Section 1 General Information 3 34 Installation MN1230...
Page 94: ...Section 1 General Information Specifications and Product Data 7 7 MN1230 Dimensions...
Page 102: ...Appendix B Appendix B 1 MN1230...