Section 1
General Information
Receiving & Installation 3-31
MN722
Figure 3-13 15 Speed 2-Wire Control Connection Diagram
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
ENABLE
FORWARD RUN
REVERSE RUN
*
SWITCH 1
*
SWITCH 2
*
SWITCH 3
EXTERNAL TRIP
OPTO INPUT COMMON
Programmable 0–5V Output (Factory Preset: Speed)
J1
ANALOG OUT 1
ANALOG OUT 2
OPTO OUT COMMON
OPTO OUT #1
OPTO OUT #2
OPTO OUT #3
OPTO OUT #4
1
2
3
4
5
6
7
Programmable 0–5V Output (Factory Preset: Current)
Terminal Tightening Torque = 7 Lb-in (0.8 Nm).
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
23
24
25
26
27
28
29
COMMON
+24VDC
A
A
B
B
INDEX
INDEX
+5VDC
OPTO IN POWER
OPTO OUT #1 RETURN
OPTO OUT #2 RETURN
OPTO OUT #3 RETURN
OPTO OUT #4 RETURN
COMMON
A
A
B
B
INDEX
INDEX
Not Used
Encoder
Input
Note 3
Buffered
Encoder
Output
Note 4
*
SWITCH 4
ACC/DEC/“S” SELECT 1
Note 1
Note 2
*
Refer to truth table, Table 3-9.
ANALOG GND
ANALOG INPUT 1
POT REFERENCE
ANALOG INPUT +2
ANALOG INPUT –2
No Connections
Both CLOSED= Forward
Both OPEN = Stop
* All CLOSED= Fault Reset
Refer to Figure 3-23.
Notes:
1.
Refer to Analog Outputs.
2.
Refer to Opto Isolated Outputs.
3.
Refer to Encoder Installation.
4.
Refer to Buffered Encoder Output.
J1-8
OPEN disables the control & motor coasts to a stop.
CLOSED allows current to flow in the motor and produce torque.
J1-9
OPEN motor decels or coasts to stop (depending on Keypad Stop mode parameter
setting).
CLOSED operates the motor in the Forward direction (with J1-10 open).
J1-10
OPEN motor decels or coasts to stop (depending on Keypad Stop mode parameter
setting).
CLOSED operates motor in the Reverse direction (with J1-9 open).
J1-11 to
Selects programmed preset speeds as defined
J1-14
in Table 3-9.
J1-15
Selects ACC/DEC group. OPEN selects group 1. CLOSED selects group 2.
J1-16
OPEN causes an external trip to be received by control. The control will disable and
display external trip when programmed “ON”. When this occurs, the drive is disabled
and an external trip fault is displayed on the keypad display (also logged into the fault
log). If J1-16 is connected, you must set Level 2 Protection block, External Trip to “ON”.
J1-39 &
Jumper as shown to power the Opto Inputs from the in24VDC supply.
40
Summary of Contents for 22H series
Page 5: ...Section 1 General Information iv Table of Contents MN722...
Page 105: ...Section 1 General Information 5 22 Troubleshooting MN722...
Page 109: ...Section 1 General Information 6 4 Manual Tuning the Series 22H Control MN722...
Page 137: ...Section 1 General Information A 8 Appendix A MN722...
Page 138: ...Appendix B Appendix B 1 MN722...