Section 1
General Information
Programming & Operation 4-9
MN722
Program Mode Continued
Reset Parameters to Factory Settings
Sometimes it is necessary to restore the parameter values to the factory settings. Follow
this procedure to do so. Be sure to change the Level 2 Motor Data block “Motor Rated
Amps” to the correct value after this procedure (restored factory setting is 999).
Note: All specific application parameters already programmed will be lost when
resetting the control to factory settings.
Note: After factory settings are restored, the drive must be re-tuned.
Action
Description
Display
Comments
Apply Power
Keypad Display shows this
opening message.
Logo display for 5 seconds.
If no faults and programmed for
LOCAL operation.
Display mode. Stop LED on.
Press PROG key
Enter program mode.
Press
Y
or
B
key
Scroll to Level 2 Blocks.
Press ENTER key
Select Level 2 Blocks.
Press
Y
or
B
key
Scroll to the Miscellaneous block.
Press ENTER key
Select Miscellaneous block.
Press
Y
key
Scroll to Factory Settings
parameter.
Press ENTER key
Access Factory Settings
parameter.
V
represents blinking cursor.
Press
Y
key
Scroll to YES, to choose original
factory settings.
Press ENTER key
Restores factory settings.
“Loading Presets” is first message
“Operation Done” is next
“No” is displayed last.
Press
Y
key
Scroll to menu exit.
Press ENTER key
Return to Level 1 blocks.
Exit Level 2 blocks.
Press
Y
or
B
key
Scroll to Programming exit.
Exit Programming mode and
return to Display mode.
Press ENTER key
Return to display mode.
Display mode. Stop LED on.
Summary of Contents for 22H series
Page 5: ...Section 1 General Information iv Table of Contents MN722...
Page 105: ...Section 1 General Information 5 22 Troubleshooting MN722...
Page 109: ...Section 1 General Information 6 4 Manual Tuning the Series 22H Control MN722...
Page 137: ...Section 1 General Information A 8 Appendix A MN722...
Page 138: ...Appendix B Appendix B 1 MN722...