Section 1
General Information
Receiving & Installation 3-39
MN722
Figure 3-18 Process Mode Connection Diagram
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Enable
Forward Enable
Reverse Enable
Table Select
Speed/Torque
Process Mode Enable
External Trip
Opto Input Common
Programmable 0–5V Output (Factory Preset: Speed)
J1
ANALOG GND
ANALOG INPUT 1
POT REFERENCE
ANALOG INPUT +2
ANALOG INPUT –2
ANALOG OUT 1
ANALOG OUT 2
Opto Out Common
OPTO OUT #1
OPTO OUT #2
OPTO OUT #3
OPTO OUT #4
1
2
3
4
5
6
7
Programmable 0–5V Output (Factory Preset: Current)
Terminal Tightening Torque = 7 Lb-in (0.8 Nm).
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
23
24
25
26
27
28
29
COMMON
+24VDC
A
A
B
B
INDEX
INDEX
+5VDC
OPTO IN POWER
OPTO OUT #1 RETURN
OPTO OUT #2 RETURN
OPTO OUT #3 RETURN
OPTO OUT #4 RETURN
COMMON
A
A
B
B
INDEX
INDEX
Not Used
Encoder
Input
Note 5
Buffered
Encoder
Output
Note 6
Jog
Fault Reset
Note 2
Note 1
Note 3
Note 4
Refer to Figure 3-23.
Notes:
1.
Refer to Analog Inputs.
2.
Refer to Analog Outputs.
3.
Refer to Opto Isolated Outputs.
4.
Refer to Figure 3-21 for 4-20mA.
5.
Refer to Encoder Installation.
6.
Refer to Buffered Encoder Output.
5k
W
Command Pot
or 0-10VDC
±
5VDC or
±
10VDC or
4-20mA
J1-8
OPEN disables the control & motor coasts to a stop.
CLOSED allows current to flow in the motor and produce torque.
J1-9
OPEN to disable forward operation.
CLOSED enables the motor in the Forward direction.
J1-10
OPEN disable reverse operation.
CLOSED enables motor in the Reverse direction.
J1-11
OPEN = TABLE 0, CLOSED = TABLE 1.
J1-12
OPEN, the control is in velocity mode.
CLOSED, the control is in torque mode.
J1-13
CLOSED to enable the Process Mode.
J1-14
CLOSED places control in JOG mode. The control will only JOG in the forward
direction.
J1-15
OPEN to run.
CLOSED to reset a fault condition.
J1-16
OPEN causes an external trip to be received by control. The control will disable and
display external trip when programmed “ON”. When this occurs, the drive is disabled
and an external trip fault is displayed on the keypad display (also logged into the fault
log). If J1-16 is connected, you must set Level 2 Protection block, External Trip to “ON”.
J1-39 &
Jumper as shown to power the Opto Inputs from the in24VDC supply.
40
Summary of Contents for 22H series
Page 5: ...Section 1 General Information iv Table of Contents MN722...
Page 105: ...Section 1 General Information 5 22 Troubleshooting MN722...
Page 109: ...Section 1 General Information 6 4 Manual Tuning the Series 22H Control MN722...
Page 137: ...Section 1 General Information A 8 Appendix A MN722...
Page 138: ...Appendix B Appendix B 1 MN722...