Table 5-2 Power Output Control Board Fault Messages
FAULT MESSAGE
DESCRIPTION
Current Sens FLT
Defective phase current sensor or open circuit detected between control board and current
sensor.
DC Bus High
Bus over voltage condition occurred.
DC Bus Low
Bus under voltage condition occurred.
Encoder Loss
Encoder coupling slipping or broken; noise on encoder lines, encoder power supply loss or
defective encoder.
External Trip
An open circuit on J1-16 typically indicating an external over temperature condition.
Following Error
Excessive following error detected between command and feedback signals.
GND FLT
Low impedance path detected between an output phase and ground.
INT Over-Temp
Temperature of control heatsink exceeded safe level.
Invalid Base ID
Control does not recognize power base ID.
Inverter Base ID
Control board installed on power base without current feedback.
Line Regen FLT
Indicates a converter section fault.
Logic Supply FLT
Logic power supply not working properly.
Lost User Data
Battery backed RAM parameters have been lost or corrupted.
When fault cleared (Reset), the control should reset to factory preset values.
Low INIT Bus V
Insufficient bus voltage on startup.
Memory Error
EEPROM error occurred. Contact Baldor.
New Base ID
Control board sensed a different power base since last time it was powered up.
No Faults
Fault log is empty.
No EXB Installed
Programmed parameter requires an expansion board.
Over Current FLT
Instantaneous over current condition detected by bus current sensor.
Overload - 1 min
Output current exceeded 1 minute rating.
Overload - 3 sec
Output current exceeded 3 second rating.
Over speed
Motor RPM exceeded 110% of programmed MAX Motor Speed.
m
P Reset
Power cycled before the residual Bus voltage reached 0VDC.
PWR Base FLT
Desaturation of power device occurred or bus current threshold exceeded.
Resolver Loss
Resolver feedback problem is indicated (if resolver used).
Torque Prove FLT
Unbalanced current between all 3 motor phases.
User Fault Text
Custom software operating fault occurred.
Summary of Contents for 22H series
Page 5: ...Section 1 General Information iv Table of Contents MN722...
Page 105: ...Section 1 General Information 5 22 Troubleshooting MN722...
Page 109: ...Section 1 General Information 6 4 Manual Tuning the Series 22H Control MN722...
Page 137: ...Section 1 General Information A 8 Appendix A MN722...
Page 138: ...Appendix B Appendix B 1 MN722...