UMAX030211 Version 1.0.2. Preliminary Documentation – May be subject to change
12 - 85
1.
Overview of The Controller
Figure 1 – AX030210 Block Diagram
The 12 Input, 8 Signal Outputs & 1 Relay Output Controller with CANopen (later 12IN-8SOUT-CO)
is designed for extremely versatile control of up to eight signal outputs for generating control signals
and one relay output to drive other loads. Its flexible circuit design gives the user a wide range of
configurable input and output types. The sophisticated control algorithms allow the user to program
the controller for a wide range of applications without the need for custom software.
The controller has ten Universal inputs that can be configured to measure analog voltage or current,
frequency/PMW or digital signal, one resistive input capable of measuring resistances from 25Ω to
250kΩ and one Digital input that can be configured to measure digital on/off signals. Measured input
data can be sent to CANopen Network or used to drive outputs directly or through the configurable
control algorithms.