UMAX030211 Version 1.0.2. Preliminary Documentation – May be subject to change
79 - 85
Note that the bootloader is NOT Arbitrary Address Capable. This means that if you want to have
multiple bootloaders running simultaneously (not recommended) you would have to manually
change the address for each one before activating the next, or there will be address conflicts. And
only one ECU would show up as the bootloader. Once the ‘active’ bootloader returns to regular
functionality, the other ECU(s) would have to be power cycled to re-activate the bootloader feature.
3. Select the
F
lashing button and navigate to where you had saved the
AF-19135-x.xx.bin
(or
equivalent) file sent from Axiomatic. (Note: only binary (.bin) files can be flashed using the EA
tool.)
4. Once the Flash Application Firmware window opens, you can enter comments such as
“Firmware upgraded by [Name]” if you so desire. This is not required, and you can leave the field
blank if you do not want to use it.
Note: You do not have to date/time-stamp the file, as this is done automatically by the EA tool when
you upload the new firmware.