UMAX030211 Version 1.0.2. Preliminary Documentation – May be subject to change
68 - 85
4.4.24.
2453h PID Target Source
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2453
0
UINT8
RO
No
2
2
Number of subindexes
1…2
RW
0-10
0
By default disabled. See Table 23
4.4.25.
2454h PID Target Number
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2454
0
UINT8
RO
No
2
2
Number of subindexes
1…2
RW
0-16
1
By default disabled. See Table 23
4.4.26.
2455h PID Feedback Source
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2455
0
UINT8
RO
No
2
2
Number of subindexes
1…2
RW
0-10
0
By default disabled. See Table 23
4.4.27.
2456h PID Feedback Number
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2456
0
UINT8
RO
No
2
2
Number of subindexes
1…2
RW
0-16
1
By default disabled. See Table 23
4.4.28.
2457h PID Control Response
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
4257
0
UINT8
RO
No
2
2
Number of subindexes
1…2
RW
0-3
0
Additional PID controller response selection
4.4.29.
2460h PID Output FV
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
4260
0
UINT8
RO
No
2
2
Number of subindexes
1…2
INT16
0-1000
0
Additional PID controller output FV
4.4.30.
2500h EC Extra Received PV
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
2500
0
UINT8
RO
Yes
9
9
Number of subindexes
1…9
INT16
RW
INT16
0
Extra received PV #1 … #9