6
Rainier 3G Plus
– (Q card) / Rainier 3G Plus – (1 card)
640
×
480 (VGA) 60Hz
Note: If the Rainier 3G Plus-1 is in cascade mode, the output resolution
can only support 720p/1080p at 50Hz/60Hz.
SDI
(BNC connector)
User configurable:
1920
×
1080 50Hz/60Hz Progressive (4:2:2 YUV / 10-bit)
1280
×
720 50Hz/60Hz Progressive (4:2:2 YUV / 10-bit)
Note:
1. If the Rainier 3G Plus-1 is in cascade mode, the output resolution can
only support 720p/1080p at 50Hz/60Hz.
2. Complying with the HDCP license, HDCP video cannot be converted
to SDI.
Table 1-3
Rainier 3G Plus
– (Q Card) / Rainier 3G Plus – (1 Card) Specifications
Rainier 3G Plus
– (PI card)
Output
SDI
(BNC connector)
This card
’s sole purpose is to convert a 1080p source signal to a 1080i
50/59.94/60 Hz output signal. Cascade input from control board can
also be routed to the PI card for conversion.
Table 1-4
Rainier 3G Plus
– (PI Card) Specifications
Rainier 3G Plus
– (Control card)
Control interface
(serial connector)
For connecting to TSL port of the TSL controller for TSL interface
Cascade
(BNC connector)
For multimedia input coming from SDI Out port (cascadable to any other
Rainier 3G Plus
– (1 card); but not cascadable to Rainier 3G Plus – (Q
card))
LTC
(BNC connector)
Linear (or Longitudinal) Time Code input
(encoding of SMPTE Time Code data in an audio signal)
Electrical: Single End
Impedance: >30k ohms
Sensitivity: 500 mV pk-pk (5V maximum)
Audio
(Headphone jack)
Analog Audio (audio out port)
Stereo
Power
Power consumption is 110 Watt (maximum)
Power Supply:
24 V DC 120 Watt adapter
Dimensions/Weight
Dimensions: 439×310×44.4 mm (17.3×12.2×1.8 inch)
Weight: 4.2 kg (9.3 lb)
Environment/Safety
Temperature:
Operating: 0
C (32
F) to 40
C (104
F)
Storage:
–10
C (14
F) to 50
C (122
F)
Humidity: 0% to 80% relative, non-condensing
Safety: FCC/CE/C-Tick/Class A
Pass MIL-STD-810G test method 514.6 for US truck under random
vibration while in operation
Table 1-5
Rainier 3G Plus
– (Control Card) Specifications