4-14
Packet Reference Manual
Classification: Avery Dennison – Public
U s ing Op t ion 51 ( P DF417 Se cur i ty /T runca t ion )
Define a s ec urity level and c hoos e whether or not to trunc ate a PDF417 bar c ode. Higher s ec urity
levels add data to a bar c ode, im proving s c an reliability. Som e dam aged bar c odes m ay s till be
s c annable if the s ec urity level is high enough. Us e this option to c reate s tandard PDF417 bar
c odes or us e the trunc ated option to c reate a narrower bar c ode. This option c an appear only
onc e per PDF417 field, in any order, following the bar c ode field.
As the s ec urity level is inc reas ed, s o is the s iz e of the PDF417 bar c ode. For eac h level
inc reas ed, the bar c ode doubles in s iz e.
Syntax
R,5 1 ,security,s tand/default |
R1. R
Option Header.
R2. 51
Indic ates Option
51
.
R3. s ec urity
Sec urity level ranges from
0
to
8
.
0
is the default.
Higher s ec urity levels add data to a bar c ode, im proving s c an
reliability. Som e dam aged bar c odes m ay s till be s c annable if the
s ec urity level is high enough.
R4. s tand/def
Trunc ation s elec tor. S is the default. Valid values :
S
a s tandard PDF417 bar c ode
T
trunc ated
Exam ple
R,5 1 ,2 ,S |
Defines a s ec urity level of 2 for a s tandard PDF417 bar c ode.
U s ing Op t ion 52 ( P DF417 W id th /Leng th )
This option defines the im age width or length of a PDF417 bar c ode. If defining a fixed num ber of
c olum ns (width), the bar c ode expands in length. If defining a fixed num ber of rows (length), the
bar c ode expands in width. Colum n value does not inc lude s tart/s top or left/right indic ator
c olum ns . If this option does not im m ediately follow the PDF417 bar c ode field, the default
s ettings are us ed. Us e this option onc e per PDF417 bar c ode field.
Syntax
R,5 2 ,ro w/co lumn,dimensio n |
R1. R
Option Header.
R2. 52
Indic ates Option
52
.
R3. row/c olum n
Indic ates the num ber of rows or c olum ns . If rows are s pec ified,
the bar c ode expands in c olum ns , or vic e vers a.
R
Row
C
Colum n
R4. dim ens ion
The num ber of rows or c olum ns defined for the bar c ode. Valid
values :
3-90
for rows . 3 is the default for rows .
1-30
for c olum ns . 1 is the default for c olum ns .
Exam ple
R,5 2 ,C,10 |
Defines the c olum n width of 10, whic h expands the PDF417 bar c ode length by 10.
Summary of Contents for Monarch Tabletop Printer 2
Page 10: ...viii Packet Reference Manual Classification Avery Dennison Public...
Page 16: ...1 6 Packet Reference Manual Classification Avery Dennison Public...
Page 48: ...2 32 Packet Reference Manual Classification Avery Dennison Public...
Page 80: ...3 32 Packet Reference Manual Classification Avery Dennison Public...
Page 102: ...4 22 Packet Reference Manual Classification Avery Dennison Public...
Page 138: ...7 10 Packet Reference Manual Classification Avery Dennison Public...
Page 156: ...8 18 Packet Reference Manual Classification Avery Dennison Public...
Page 160: ...9 4 Packet Reference Manual Classification Avery Dennison Public...
Page 196: ...C 8 Packet Reference Manual Classification Avery Dennison Public...
Page 202: ...D 6 Packet Reference Manual Classification Avery Dennison Public...
Page 205: ......