29
Changing the Feed Pawl Spring
Turn ON air supply
1. Remove the needle block and needle guard (Illustration shows Right Module)
•
See “Changing the Knife” chapter of this manual
2. Remove feed track mounting screw and feed track
3. Remove feed pawl assembly
4. Remove pin from feed pawl assembly
5. Remove feed pawl
6. Replace feed pawl spring
Feed Pawl Assembly
1
2
3,4 &5
Feed Pawl Spring
Pin
Feed Pawl
Feed Track
Summary of Contents for IndES Elastic Staple 11600-0
Page 14: ...12 2 Needle Guard Needle Brush Block 3 Adjust LMS Stop 4 Tighten Screw...
Page 17: ...15 Staple Loading Diagram from the Reel to the Module Assembly 3 2 1 2 3 4 5 6 7...
Page 19: ...17 2 3 4 5 6 7 Aligned...
Page 29: ...27 Feed Assembly screws on back of Module Front Linkage Cover Side Cover Feed Assembly 2 3...
Page 37: ...35 Handle Assembly...
Page 38: ...36 Handle Assembly...
Page 41: ...39 Right Module Assembly...
Page 43: ...41 Right Drive Linkage Assembly...
Page 44: ...42 Right Drive Linkage Assembly...
Page 45: ...43 Right Feed Assembly...
Page 49: ...47 Left Module Assembly...
Page 51: ...49 Left Drive Linkage Assembly...
Page 52: ...50 Left Drive Linkage Assembly...
Page 53: ...51 Left Feed Assembly...