22
Clearing a Staple Jam
ü
In the event of a staple jam STOP the machine immediately and clear the jammed
staples to prevent damage to the machine
Turn ON air supply
1. Unload the staple chain as described in the earlier chapter titled “
Unloading the
Fastener from the IndES™ Module
”
If there are still staples jammed
…
2.
Turn OFF air supply
and pull down to remove the remaining jammed fasteners.
If there are still staples jammed
…
3. Remove the needle(s) and clear the Needle(s) of any staples.
4. Actuate the Module a few times to check that ejector rods are traveling properly
to the needle tip and the knives are moving in and out correctly.
5. Reload the staple chain and test for proper operation.
If there are still staples jammed
…
6. If staples fail to feed and eject properly, remove the needle block to look
for contamination.