Installing and wiring telephones and trunks
78 Installing and Connecting the MDF and Telephones
Figure 38: Digital Tie Trunk wiring
DS1 tie trunk example
Digital Signal Level 1 (DS1) tie trunks provide a 1.544 Mbps (T1) or 2.048 Mbps (E1) digital data
service between two collocated configurations or between the configuration and a data network.
See these examples:
●
Collocated DS1 interface trunks
on page 78
●
DS1 interface trunks using T1 channel service unit
on page 79
For cable descriptions, see
●
DS1 cables
on page 80
●
Pinout of C6F cable
on page 80
Collocated DS1 interface trunks
Two TN464HP DS1 Interface circuit packs can be in collocated configurations. A DS1 Interface
circuit pack in one configuration can be connected to a DS1 in another configuration. A C6D
cable can be used if the distance is less than 50 feet (15.2 meters). If the distance is between
50 feet (15 meters) and 1,310 feet (399 meters), use a C6E cable.
Note:
Note:
The maximum distance between cabinets is 1,310 feet (399 meters).
Figure notes:
1. External Trunk
2. Digital Trunk Circuit Pack
3. LO
4. LO (Balanced Output Pair)
5. LI
6. LI (Balanced Input Pair)
Summary of Contents for 03-300686
Page 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Page 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Page 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Page 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Page 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Page 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...
Page 156: ...156 Installing and Connecting the MDF and Telephones Index ...