Installing and wiring telephones and trunks
106 Installing and Connecting the MDF and Telephones
Installing external ringing
Connections for external ringing are at an information outlet. The media gateway side of the
MDF is connected to a TN2183 (or equivalent) Analog Line circuit pack. The circuitry and power
source for the device are provided by the customer.
Note:
Note:
A maximum of three devices can connect to one analog line circuit pack port.
To install external ringing:
1. Wire the ringing device to the information outlet as shown in
Figure 51: 3-pair and 4-pair
modularity
on page 106 and
Figure 41: Example adjunct power connections
on page 85.
2. Administer per the
Administrator Guide for Avaya Communication Manager
(03-300509).
Figure 51: 3-pair and 4-pair modularity
Figure notes:
1. Port Circuit Pack
2. Media Gateway Connector Pins
(3-Pair Modularity)
3. Main Distribution Frame (MDF)
Pins (3-Pair Modularity)
4. Input to Information Outlet
(4-Pair Modularity)
5. Adjunct Power
6. Output From Information Outlet
(4-Pair Modularity)
7. Voice or Data Terminal Pins
Summary of Contents for 03-300686
Page 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Page 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Page 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Page 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Page 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Page 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...
Page 156: ...156 Installing and Connecting the MDF and Telephones Index ...