Installing and wiring telephones and trunks
74 Installing and Connecting the MDF and Telephones
Figure 34: 302D to 4-wire DCP wiring
Connecting adjunct power
The 400B2 adapter is convenient for connecting local -48 VDC power to a modular plug. See
Figure 35: 400B2 Adapter connecting to a modular plug
on page 75.
Each port network can provide power for up to three attendant consoles. This source of power
is preferred for the attendant consoles because it has the same battery backup as the media
gateway. See
Auxiliary connector outputs (MCC1 and SCC1 Media Gateways only)
on page 81.
Note:
Note:
Adjunct power can be provided locally at the telephone or console by either the
1151B1 or 1151B2 power supply. Adjunct power can be provided from the
equipment room or equipment closet with the 1145B power unit. See
Installing
and wiring telephone power supplies
on page 109
for power supply information
and installation procedures.
Figure notes:
1. 302D Attendant Console
2. 4-wire Digital Line Circuit Pack
(Position 1C02)
3. -48 VDC From Adjunct Power
4. Ground From Adjunct Power
302cwire RBP 040596
1
39
14
40
15
2
3
6
7
8
TXT
TXR
PXT
PXR
TXT5
TXR5
PXT5
PXR5
Summary of Contents for 03-300686
Page 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Page 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Page 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Page 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Page 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Page 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...
Page 156: ...156 Installing and Connecting the MDF and Telephones Index ...