808A Emergency Transfer Panel and telephone installation examples
Issue 3 January 2008
105
4. Connect
ST
leads on the yellow emergency transfer row/connecting block for each
emergency transfer telephone to the assigned terminal in the blue or white station
distribution field. The
ST
terminal leads should be terminated on the following pairs: 1, 4, 7,
10, 13, 16, 19, or 22 (the first pair of any 3-pair group).
5. Install the telephone:
●
Connect telephone to the information outlet.
●
Install patch cords/jumper wires between the media gateway side and the station side of
the station distribution field on the MDF.
Installing telephones used for emergency
transfer and as normal extension (trunk/auxiliary field)
To install telephones used for emergency transfer and as a normal extension:
1. Connect a pair of wires between the
-48V
and
GRD
terminals on the yellow emergency
transfer row/connecting block to the
EM TRANS RELAY PWR
terminal. See
Figure 50: Connections for telephone used for emergency transfer and as normal
extension
on page 104.
2. Connect
CO
trunk leads from the purple field to
TC
terminals on the yellow emergency
transfer row/connecting block for each trunk.
3. Connect
CO
trunk leads from the green field to
TK
terminals on the yellow emergency
transfer row/connecting block for each trunk.
4. Connect telephone leads from the purple analog line circuit pack row/ connecting block to
the
LC
terminals on the yellow emergency transfer row/connecting block for each
telephone.
5. Connect
ST
leads on the yellow emergency transfer row/connecting block for each
emergency transfer telephone to the assigned terminal in the blue or white station
distribution field.
6. Install the telephone:
●
Connect telephone to the information outlet.
●
Install patch cords/jumper wires between the media gateway side and the station.
Summary of Contents for 03-300686
Page 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Page 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Page 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Page 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Page 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Page 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...