1145B2 power supply
Issue 3 January 2008
115
Installing the battery mounting/wiring
Three types of back-up batteries are used. See
Table 19: Back-up battery rating
on page 115
for the battery type and rating. To install the battery mounting and wiring:
1. Insert two #10-32 x 1/2-inch shoulder screws into the top designated battery holes on the
wall mounting plate. Lightly screw in but do not tighten.
2. Place the keyhole slots in the battery bracket on these two screws. The battery cord exits
from the right of the bracket. Make sure the label on the battery is visible. Tighten the
screws securely.
3. Plug the battery cord into the power supply’s right rear receptacle. The rear receptacle is
indicated on the right label.
Installing the expanded power distribution unit
A second power distribution unit can be installed to provide power to additional devices.
!
CAUTION:
CAUTION:
Total power cannot exceed 275 watts. The maximum ISDN terminal mixture is 24,
7500-series
and 24, 8500-series terminals.
The maximum DCP terminal mixture is 24, 7400-series and 24, 8400-series or
64, 8400-series terminals.
The expanded power distribution unit kit contains:
●
One 1146B2 Power Distribution Unit
●
One “T” Cable
●
Two #8-32 x 1/2-in. Shoulder Screws
●
One #8-32 x 1-in. Screw
●
One spacer bracket
Table 19: Back-up battery rating
Battery
Rating
1148B
2.5 amp-hours
1149B
5 amp-hours
1147B
8 amp-hours
Summary of Contents for 03-300686
Page 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Page 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Page 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Page 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Page 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Page 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...
Page 156: ...156 Installing and Connecting the MDF and Telephones Index ...