Connecting telephones
Issue 3 January 2008
73
Connecting a typical telephone
The 302D Enhanced Attendant Console is used to describe a telephone connection typically
used with the 84xx (4-wire) telephones.
The 302D does not require auxiliary power unless it has a 26C1 DXS console or Vacuum
Fluorescent Display. The 302D attendant console always requires auxiliary (adjunct) power (-48
VDC). Power is connected to the console through Pins 7 and 8 of the information outlet. Only
three consoles can be powered by the media gateway. When possible, the primary console
should be powered from the media gateway so it has the same power failure backup as the
media gateway.
The maximum cabling distance for the console powered from the media gateway is 350 feet
(100 meters).
The general steps to connect a telephone are:
1. Choose a device to connect such as a 302D Attendant Console.
2. Choose the port circuit pack and its slot number, such as cabinet 1, slot 02.
3. Choose a port circuit on the port circuit pack, such as Port 05.
4. Install cross-connect jumpers to wire the terminal to the port circuit pack. See
Figure 34: 302D to 4-wire DCP wiring
on page 74. This pinout is for the TN754C DCP
Digital Line 4-wire circuit pack.
!
CAUTION:
CAUTION:
Do not use the 329A power unit for the attendant console. Use an 1151B1,
1151B2, 1145A, or MSP-1 power unit.
5. For terminals needing adjunct power, wire -48 VDC and ground to appropriate pins on the
terminal. See
Figure 34: 302D to 4-wire DCP wiring
.
Summary of Contents for 03-300686
Page 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Page 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Page 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Page 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Page 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Page 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...
Page 156: ...156 Installing and Connecting the MDF and Telephones Index ...