Testing the complete configuration
146 Installing and Connecting the MDF and Telephones
Testing terminating trunk transmission
The terminating trunk transmission test provides for extension number access to 3 tone
sequences that can be used for trunk transmission testing from the distant end of the trunks. To
test terminating trunk transmission:
1. Type
change system-parameters maintenance
and press
Enter
and go to screen 2.
2. Under TERMINATING TRUNK TRANSMISSION TEST (Extension), type in 3 extension
numbers in the 3 fields provided:
Test Type 100:_______Test Type 102:_______Test Type 105:_______
Test type
Test features
Test type
100
5.5 seconds of 1004 Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute
Test Type
102
9 seconds of 1004 Hz tone at 0 dB
1 second of silence
Cycle is repeated until disconnect, which is forced after
24 hours
Test Type
105
9 seconds of 1004 Hz tone at -16 dB
1 second of silence
9 seconds of 404 Hz tone at -16 dB
1 second of silence
9 seconds of 2804 Hz tone at -16 dB
30 seconds of silence
0.5 seconds of test progress tone (2225 Hz)
About 5 seconds of silence
Forced disconnect
Summary of Contents for 03-300686
Page 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...
Page 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...
Page 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...
Page 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...
Page 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...
Page 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...
Page 156: ...156 Installing and Connecting the MDF and Telephones Index ...