ATTO FibreBridge Software Manual
- -
51
ATTO Technology, Inc.
Buffer ID nvram offset Buffer Description (default values*)
Bit0: Auto Speed Detect
1=Speed Detection Enabled 0=SpeedDetection Disabled
25:
0x51
Temperature High Warning
(default: 0x28)
A user definable SBYTE parameter that indicates when certain alarm flags should be set
within SCSI Enclosure Services with respect to excessive temperature. The default
Temperature High Warning is 40 degrees Celsius.
26:
0x52
Temperature Low Warning
(default: 0x05)
A user definable SBYTE parameter that indicates when certain alarm flags should be set
within SCSI Enclosure Services with respect to excessive temperature. The default
Temperature Low Warning is 5 degrees Celsius.
27:
0x53
Event Logging Flags
(default 0x02)
Bits 7-2: Reserved
Bit 1: Event Status Flag 1 = Log all events 0 = Log events with status other than good
Bit 0: Enabled Flag
1 = Logging enabled 0 = Logging disabled
28:
0x54
Event Logging Subsystem
(default 0x3F)
Bit 7-6: Reserved
Bit 5: NVRAM & Flash
1 = Logging enabled 0 = Logging disabled
Bit 4: GBIC Connector
1 = Logging enabled 0 = Logging disabled
Bit 3: Reserved
Bit 2: Ethernet
1 = Logging enabled 0 = Logging disabled
Bit 1: SCSI Processor/i960 1 = Logging enabled 0 = Logging disabled
Bit 0: FCP Processor/i960 1 = Logging enabled 0 = Logging disabled
29 0x55
Event Logging Level
(default 0x3F)
Bit 7-6: Reserved
Bit 5: Debug, ATTO tracking events 1 = Logging enabled 0 = Logging disabled
Bit 4: Other, otherwise not categorized 1 = Logging enabled 0 = Logging disabled
Bit 3: Failure, hard failure 1 = Logging enabled 0 = Logging disabled
Bit 2: Critical, operation limited/curtailed 1 = Logging enabled 0 = Logging disabled
Bit 1: Warning, unexpected situation/condition 1 = Logging enabled0 = Logging disabled
Bit 0: Info, general information 1 = Logging enabled 0 = Logging disabled
2a
0x56
Event Displaying Flags
(default 0x02)
Bits 7-2: Reserved
Bit 1: Event Status Flag 1 = Display all events 0 = Display events with status other than
good
Bit 0: Reserved
2b
0x57
Event Displaying Subsystem
(default 0x3F)
Bit 7-6: Reserved
Bit 5: NVRAM & Flash
1 = Displaying enabled
0 = Displaying disabled
Bit 4: GBIC Connector
1 = Displaying enabled
0 = Displaying disabled
Bit 3: Reserved
Bit 2: Ethernet
1 = Displaying enabled
0 = Displaying disabled
Bit 1: SCSI Processor/i960
1 = Displaying enabled
0 = Displaying disabled
Bit 0: FCP Processor/i960 1 = Displaying enabled
0 = Displaying disabled
2c 0x58
Event Displaying Level
(default 0x3F)
Bit 7-6: Reserved
Bit 5: Debug, ATTO tracking events 1 = Displaying enabled 0 = Displaying disabled
Bit 4: Other, otherwise not categorized 1 = Displaying enabled 0 = Displaying disabled
Bit 3: Failure, hard failure 1 = Displaying enabled 0 = Displaying disabled
Bit 2: Critical, operation limited/curtailed 1 = Displaying enabled 0 = Displaying disabled
Bit 1: Warning, unexpected situation/cond. 1 = Displaying enabled 0 = Displaying
disabled
Bit 0: Info, general information1 = Displaying enabled
0 = Displaying disabled
*Reserved fields/bits generally are set to 0 and are not user definable.
Summary of Contents for FibreBridge 2200D
Page 2: ...ATTO Technology Inc ATTO FibreBridge Software Manual i ATTO Technology Inc...
Page 5: ...ATTO Technology Inc ATTO FibreBridge Software Manual iii ATTO Technology Inc...
Page 7: ...ATTO Technology Inc ATTO FibreBridge Software Manual 2 ATTO Technology Inc...
Page 9: ...ATTO Technology Inc ATTO FibreBridge Software Manual 4 ATTO Technology Inc...
Page 66: ...ATTO Technology Inc ATTO FibreBridge Software Manual 3 ATTO Technology Inc...