![ATTO Technology FibreBridge 2200D Software Manual Download Page 45](http://html1.mh-extra.com/html/atto-technology/fibrebridge-2200d/fibrebridge-2200d_software-manual_3005631045.webp)
ATTO Technology, Inc.
ATTO FibreBridge Software Manual
- -
40
ATTO Technology, Inc.
Enclosure Control Page for ATTO FibreBridge 3100R and 3200R
Byte
0
1
2
3
0
02
Cond. Bits
00
0x48
4
Generation Code
8
Overall Control – Device
12
Element Control – Device
16
Overall Control – Power Supply
20
Element Control – Power Supply A
24
Element Control – Power supply B
28
Overall Control – Temperature Sensor
32
Element Control – Temperature Sensor
36
Overall Control – SCSI Ports
40
Element Control – SCSI Port 1
44
Element Control – SCSI Port 2
48
Overall Control – Language
52
Element Control – Language
56
Overall Control – GBIC Ports
60
Element Control – GBIC Port 1
64
Element Control – GBIC Port 2
68
Overall Control – POST Code
72
Element Control – POST Code
76
Overall Control – NVRAM Reset
80
Element Control – NVRAM Reset
Generation Code – must be 0.
Every Control Element starts with a Common Control byte. The common control byte is used to choose
which fields to update based on the page. If an element should be ignored by the ATTO FibreBridge, the
Select bit must be 0. Conversely, to tell the ATTO FibreBridge to implement the changes specified in the
Control Element, the Select Bit should be set to 1.
Common Control is defined as follows:
Bit
Byte
7
6
5
4
3
2
1
0
0
Select
Reservd
DISABLE
Reservd
Reserved
SELECT – Set to 1, signals the ATTO FibreBridge that the Control Element should be used to change
ATTO FibreBridge Configruation. Set to 0, signals the ATTO FibreBridge to ignore the Control Element.
DISABLE – used in the Temperature Control Element to stop the ATTO FibreBridge from raising an
error based on over/undertemp status.
For Example, to Disable SCSI Port 1 only, and leave the rest of the configuration the same, All Overall
Control and Element Control Fields should have the Select bit CLEARED, except for the SCSI Port 1
Element, which should have the Select bit SET and the disable bit in byte 3 SET.
Summary of Contents for FibreBridge 2200D
Page 2: ...ATTO Technology Inc ATTO FibreBridge Software Manual i ATTO Technology Inc...
Page 5: ...ATTO Technology Inc ATTO FibreBridge Software Manual iii ATTO Technology Inc...
Page 7: ...ATTO Technology Inc ATTO FibreBridge Software Manual 2 ATTO Technology Inc...
Page 9: ...ATTO Technology Inc ATTO FibreBridge Software Manual 4 ATTO Technology Inc...
Page 66: ...ATTO Technology Inc ATTO FibreBridge Software Manual 3 ATTO Technology Inc...