177
6174B–ATARM–07-Nov-05
AT91FR40162S Preliminary
19.3
Flash DC Characteristics
Note: 1.
In the erase mode, I
CC
is 45 mA.
19.4
Flash Operating Modes
Notes:
1. X can be V
IL
or V
IH
.
2. Manufacturer Code: 001FH , Device Code: 00C0H
3. V
IHPP
(min) = 0.9V; V
IHPP
(max) = 3.6V.
4. V
ILPP
(max) = 0.4V.
Table 19-3.
Flash DC Characteristics
Symbol
Parameter
Condition
Min
Typ
Max
Units
I
LI
Input Load Current
V
IN
= 0V to V
CC
2
µA
I
LO
Output Leakage Current
V
I/O
= 0V to V
CC
10
µA
I
SB
V
CC
Standby Current CMOS
CE = V
CC
- 0.3V to
V
CC
13
25
µA
I
CC
V
CC
Active Read Current
f = 5 MHz; I
OUT
= 0
mA
12
25
mA
I
CC1
V
CC
Programming Current
40
mA
I
PP1
V
PP
Input Load Current
5
µA
V
IL
Input Low Voltage
0.6
V
V
IH
Input High Voltage
2.0
V
Table 19-4.
Flash Operating Modes
Mode
CE
OE
WE
RESET
V
PP
Ai
I/O
Read
V
IL
V
IL
V
IH
V
IH
X
Ai
D
OUT
Program/Erase
V
IL
V
IH
V
IL
V
IH
V
IHPP
Ai
D
IN
Standby/Program Inhibit
V
IH
X
X
V
IH
X
X
High-Z
Program Inhibit
X
X
V
IH
V
IH
X
X
V
IL
X
V
IH
X
X
X
X
V
IH
V
ILPP
Output Disable
X
V
IH
X
V
IH
X
High-Z
Reset
X
X
X
V
IL
X
X
High-Z
Product Identification
Software
V
IH
A0 = V
IL
, A1 - A19 = V
IL
Manufacturer
Code
A0 = V
IH
, A1 - A19 = V
IL
Device Code