Z97-WS
3-49
Chapter 3
Chassis Fan 1/4 Lower Temperature [40]
Use the <+> or <-> keys to adjust the chassis fans’ lower temperature. The
values range from 40
°
C to 75
°
C..
Chassis Fan 1/4 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum chassis fan duty cycle. The
values range from 60% to 100%. When the chassis temperature is under
40
°
C, the chassis fan operates at the minimum duty cycle.
Anti Surge Support [Enabled]
This item allows you to enable or disable the OVP (Over Voltage Protection) and UVP (Under
Voltage Protection) functions. This causes the system to automatically shut down when the
voltage exceeds the safe range that protects the motherboard’s components.
Configuration options: [Disabled] [Enabled]