2.3 Motor outline and mounting dimensions
Note:
Motor structural dimensions may vary with design modification. If you are sensitive to motor
mounting dimensions, check the dimensions with sales staff before ordering. In this section, if not
otherwise specified, all the dimensions are expressed in millimeterm).
2.3.1 For base-60 motors
¦ µ
70
M5*10
2
¦ µ
16.6
¦ µ
14
+0
-0.011
(h6)
5
+0
-0.03
(h9)
5
11
R5.25
20
4-¦ µ
5.5 (Equally spaced) Through-hole
45°
45
.
5
60
L
30
3
¦µ
50
+0 -0
.0
25
(h
7
)
Motor model
(with multiturn absolute encoder)
L (mm)
Without brake
With permanent magnet
brake
AS64MT
□
20C2-A
115
152
AS64MT
□
20C4-A
139
176
2.3.2 For base-80 motors
M5*10
6
+0
-0 . 03
(h9)
15.5
6
2
¦ µ
19.5
¦ µ
19
+0
-0 . 01 3
(h6)
R10
¦µ
70
+0 -0
.
03
(h7)
22
55.5
¦ µ
90
4-
¦ µ
7 (Equally spaced) Through-hole
10
35
3
L
Motor model
(with multiturn absolute encoder)
L (mm)
Without brake
With permanent magnet
brake
AS64MT
□
20C7-A
140
186.5