AS64 series AC servo drive Function codes
-181-
P6.05
Reverse high
jogging speed
Setting range
Default
Unit
Applicable
mode
-6000
–0
-60
r/min
P
This parameter specifies the speed of fast reverse jogging, which is triggered by the reverse
jogging terminal and high-low jogging speed switching terminal.
P6.05
Data size
16bit
Data format
DEC
Modbus address
2210, 2211
CANopen address
0x2605, 0x00
P6.06
Enable terminal
jogging
Setting range
Default
Unit
Applicable
mode
0
–1
0
-
P
This parameter specifies whether to enable terminal jogging.
Setting
Meaning
[
0
]
Disable
1
Enable
P6.06
Data size
16bit
Data format
DEC
Modbus address
2212, 2213
CANopen address
0x2606, 0x00
P6.20
1
Turret switch
Setting range
Default
Unit
Applicable
mode
0
–1
0
-
P
This parameter specifies whether to enable the turret switch.
Setting
Meaning
[
0
]
Disable
1
Enable
P6.20
1
Data size
16bit
Data format
DEC
Modbus address
2240, 2241
CANopen address
0x2614, 0x00
P6.21
Knives per turret
Setting range
Default
Unit
Applicable
mode
1
–128
16
-
P
This parameter specifies the number of knives in a turret.
P6.21
Data size
16bit
Data format
DEC
Modbus address
2242, 2243
CANopen address
0x2615, 0x00
P6.22
Pulses per turret
rotation
Setting range Default
Unit
Applicable
mode
2
–(2
31
-1)
10000
reference unit
P