AS64 series AC servo drive Function codes
-96-
Modbus address
1084, 1085
CANopen address
0x202A, 0x00
P0.43
Reverse of AI 1
Setting range
Default
Unit
Applicable
mode
0–1
0
-
P
S
T
This parameter specifies the voltage polarity of analog input 1.
Setting
Actual detection result
[
0
]
Positive polarity
[+Voltage]→[Positive value],[- Voltage]→[Negative
value]
1
Negative polarity
[+Voltage]→[Negative value],[- Voltage]→[Positive
value]
P0.43
Data size
16bit
Data format
DEC
Modbus address
1086, 1087
CANopen address
0x202B, 0x00
P0.45
Dead zone of AI 1
Setting range
Default
Unit
Applicable
mode
0.000–3.000
0.000
V
P
S
T
If the absolute voltage value of analog input 1 falls in the range of this parameter, the
corresponding command value is 0.
P0.45
Data size
16bit
Data format
DEC
Modbus address
1090, 1091
CANopen address
0x202D, 0x00
P0.46
Internal speed 1/speed
limit 1
Setting range
Default
Unit
Applicable
mode
-20000–20000
100
r/min
S
T
P0.47
Internal speed 2/speed
limit 2
Setting range
Default
Unit
Applicable
mode
-20000–20000
0
r/min
S
T
P0.48
Internal speed 3/speed
limit 3
Setting range
Default
Unit
Applicable
mode
-20000–20000
0
r/min
S
T
P0.49
Internal speed 4/speed
limit 4
Setting range
Default
Unit
Applicable
mode
-20000–20000
0
r/min
S
T
P0.50
Internal speed 5
Setting range
Default
Unit
Applicable
mode
-20000–20000
0
r/min
S
P0.51
Internal speed 6
Setting range
Default
Unit
Applicable
mode