CAUTION – BEFORE STARTING:
• Check hand of door (This device is handed and not reversible)
• Door should be fitted and hung
• Verify box label for size of exit device, function and hand
Chassis
arm
Cover
(1) #10-
24 3/4”
Machine
screws
Center case
chassis
Mounting bracket
Top
case
Top bolt’s
flat
Top
bolt
Top
rod
Threaded
bushing
Inner
chassis
Bottom
rod
Spring
Sleeve
Bottom
bolt
Bottom
plate
Wire
holder
IMPORTANT: Surface of door where
exit device is to be applied must be
flush. Clear away any raised projections
to allow exit device to rest on flat
surface of door
INSTALLING RODS INTO DOOR
1. Screw top rod and bottom rod into inner chassis and slide this assembly into
the door being careful not to damage wire and connector
2. Slide wire and connector through the wire opening in the door
3. Attach the inner chassis to the door with (2) Fillister head screws
NOTE: If 700 ET Series Control is used, mount ET control next
ATTACH CHASSIS
1. Feed wire and connector through chassis as shown
2. Snap the Electrolynx connectors together and gather excess wire in the top
section of the chassis. Wire tie in place
3. Finish installation per instruction sheet A7002 and Section 10 within this manual
8400 Rod Assy Bottom Dwg Door Installation
8400 Rod Assy Bottom Dwg Door Installation
Lock Down Key —
7/32” hex key
To operate: Depress
pushrail, insert hex key
and turn clockwise.
(Not furnished with 12-)
Rail wire
connector
Wire &
connector
(2) #10 x 1-1/4”
Machine screw
Rail
assembly
Push rail
PREPARE DOOR and install rods and chassis –
Refer to Instruction sheet A7002
Installing 59-MD8600/12-59-MD8600 Concealed Vertical Rod Exit Devices
Exit Device Installation (continued)