Exit Device Installation
9
Electroguard
(59-, 12-59-)
80 Series Rail
with 8 and 4-pin connectors
and 3 loose wires
4 2
3 1
1, Violet (RAR - NC)
2, Grey (LBM - C)
4, Tan (LBM - NC)
3, Pink (LBM - NO)
Red/Green (Voice/Gang - C)
1
7
5
6 4
3
2
8
1, Black (-24)
2, Red (+24)
4, Green (EG)
3, White (FA)
5, Orange (EI)
7, Brown (RAR - C)
8, Yellow (RAR - NO)
6, Blue (DS)
Red/Black (Voice/Gang - NC)
Red/Yellow (Voice/Gang - NO)
Note: RAR, LBM and Voice/Gang contacts
shown are with power applied to rail
B. ElectroLynx Connector System Notes:
The system is designed to be installation friendly with
pluggable connectors from the electric hinge through the
door to the rail. The only wiring required is to the loose
wires on the pigtail harness assembly on the frame side
of the electric hinge
IMPORTANT:
The plug and receptacle connectors are designed to
mate and lock together as shown in the figure. Plug the
connectors into each other with the locking mechanism
aligned as indicated
Do NOT force connectors on any other way
A. IMPORTANT
Caution: Disconnect all input power before beginning installation to prevent electrical
shock and equipment damage
1. Installer must be a trained, experienced service person
2. All wiring must comply with applicable local electrical codes, ordinances and regulations
3. Field cut rail assemblies are not allowed. Exit device must be ordered for specific door width
Plug
Locking mechanism
Receptacle