Dip switch positions 3 and 4
- Used to select the momentary egress time of 5, 10, 20 or 40 seconds. This switch is preset at
the factory for five seconds
S2 Dip Switch Position
Momentary
Egress Time
3
4
OFF
OFF
5 seconds
OFF
ON
10 seconds
ON
OFF
20 seconds
ON
ON
40 seconds
S2-1
Nuisance Delay
- (Field selectable 0 or 1 second) A one second nuisance delay can be enabled by setting Dip
Switch (S2-1) to the On position. When nuisance delay is enabled, the unit will require the push bar to be depressed
for more than one second in order to trigger an irreversible alarm condition. If the push bar is released before the 1
second has elapsed, the unit will go back into the “delayed egress mode” and the alarm will not sound. Nuisance
delay is set to On position at factory
If the Dip Switch S2-1 is in the Off position, there will be no nuisance delay and alarm horn will sound
immediately
when the push bar is depressed
S2-2
Nuisance Audible
- (Field selectable on or off) An audible horn is enabled by setting Dip Switch S2-2 to the On
position. The internal horn will sound as soon as the push bar is depressed, signaling that the device is armed. If the
pushbar is held down for more than 1 second, an irreversible alarm condition begins. If Dip Switch S2-2 is in the Off
position, the horn will not sound during nuisance delay
Nuisance audible is set to On position at factory to sound horn when rail is depressed during nuisance delay
OFF
ON
S2-1 On - 1 second nuisance delay
S2-1 Off - no nuisance delay
S2-2 On - Nuisance Audible On
S2-2 Off - Nuisance Audible Off
OFF
ON
S2-1
Select Dip Switch Settings prior to installing exit device on door
S2
Electroguard™ Dip Switch Settings