Electroguard Troubleshooting
18
The following four Diagnostic LEDs have been added to assist in installation and troubleshooting the
59- Electroguard™ device. The following table and notes explain the function of each LED.
Visible Insert LEDs
Function
Green ON only
Rail is Armed - Delayed Egress Mode
Red ON only
Rail is Disarmed – Maintained (Free) Egress Mode
Red “Flashing” Green OFF
Rail is in Momentary Egress Mode
Green and Red “Alternate”, Rail Horn is ON
Rail is in violation
Diagnostic LEDs
Function
Yellow (Latch Bolt/Rod Monitor)
ON – Latch Bolt or Vertical Rods are retracted
OFF – Latch Bolt or Vertical Rods are extended/latched
Green (Magnet)
ON – Rail Magnet is energized (+24vdc from main board)
OFF – Rail Magnet is de-energized
Red (Push Rail Switch)
ON – Rail Push Bar is depressed
OFF – Rail Push Bar is released
Orange (Door Status Switch)
ON – Door Status Switch is open. Door is open/violated
OFF – Door Status Switch is closed. Door is closed and secure
NOTES
1. With Rim and Mortise type exit devices - When the latch bolt is retracted about half way, the
Yellow
Diagnostic LED
turns ON. The LED will be ON from the half way to the fully retracted position;
otherwise the Led will be OFF
2. With Vertical Rod type exit devices – When the rods are retracted and the door is opened, the Rod Monitor
switch is activated and the
Yellow Diagnostic LED
turns ON. The LED will remain on until the door closes
and the rods are reset and engaged
3. When the rail is armed (in Delayed Egress Mode) and the door is closed and latched, the
Green Insert LED
and the
Green Diagnostic LED
should be ON only. All other LEDs should be OFF
4. With the rail armed, depressing the rail push bar slightly will turn the
Red Diagnostic LED
ON. The rail
should go into alarm immediately (no nuisance delay) or after being pressed in for 1 second (1-second
nuisance delay). The rail will be in the irreversible alarm mode –
Insert Green
and
Red LED
flash and the
rail horn sounds. After a standard delay of 15 seconds (or 30-second optional delay), the rail magnet
de-energizes and passage is allowed. The rail horn will continue to sound until the rail is reset with a key
5. When a Door Status switch is used and the door is opened the
Orange Diagnostic LED
will turn ON,
which indicates that the door is not secure. When NOT using a Door Status switch, the Blue wire should be
connected to Black (-24VDC). In this case, the LED will always be OFF