Push rail
Installing 59-8900/12-59-8900 Series Mortise Lock Exit Device
IMPORTANT: Surface of door where
exit device is to be applied must be
flush. Clear away any raised projections
to allow exit device to rest on flat
surface of door
Cover
Chassis
arm
Left Hand Reverse Bevel
Illustrated
Vertical
reverse
line (CL of
chassis)
General Touch Bar
Wire &
connector
Mortise lock
body
CAUTION – BEFORE STARTING:
• Check hand of door (This device is handed and not reversible)
• Door should be fitted and hung
• Verify box label for size of exit device, function and hand
PREPARE DOOR AND MOUNT LOCK
Refer to Instruction sheet A6705
Rail wire &
connector
Chassis
1. Feed wire and connector through the mortise opening and out the inside diameter
8300 Mount Lock Dwg
Wire & connector
Inside diameter
Inside Of
Door
Lock Down Key —
7/32” hex key
To operate: Depress
pushrail, insert hex key and
turn clockwise.
(Not furnished with 12-)
Rail assembly
Exit Device Installation (continued)